Tripp Lite single phase Metered PDU / Power Distribution Units offer real-time local reporting of load level in amps via built-in digital display. Enables visual monitoring of PDU load levels to prevent overloads as additional equipment is added. Offers reliable rackmount multi-outlet power distribution from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.- 30A single phase 208/240V Metered Power Distribution Unit / PDU (Agency derated to 24A continuous)- Set of two lighted meters report PDU output current in amps for each output load bank- Attached NEMA L6-30P 30A 208/240V input plug and 12ft / 3.6m cord- 0U 63.75in / 162cm vertical rackmount format installs using no rack spaces- 30 output receptacles (6 C19, 24 C13)- Outlets are arranged in two 15 outlet load banks, each with separate 15A breaker and current metering- Toolless installation in button-mount compatible equipment racks
Tripp Lite PDUV30-36. PDU types: Basic, Rack capacity: 0U, Type: Single-phase. AC outlets quantity: 12 AC outlet(s), AC outlet types: NEMA 5–15, NEMA 5–20R, Power plug: NEMA L5-30P. Cable length: 120.1"" (3.05 m). Nominal input voltage: 100 - 127 V, Maximum current: 30 A, AC input frequency: 50 - 60 Hz. Width: 2.19"" (55.6 mm), Depth: 3.75"" (95.2 mm), Height: 36"" (914.4 mm)
Single-Phase PDU Distributes and Monitors Network-Grade Power in Real TimeThis local metered rack PDU (rPDU) provides real-time local reporting of the total load level via its built-in digital current metering. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMV20HV-36 features 16 C13 and four C19 208/230V outlets for connecting equipment. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged. The switchless design helps prevent an accidental shutdown, which could lead to costly downtime.Digital Load Meter Helps Prevent Potentially Expensive OverloadsA digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low.Versatile Installation Options Give You Plenty of ChoicesThe 40-inch 0U PDU mounts vertically in an EIA-standard 19-inch rack using the included toolless mounting buttons or the included mounting brackets with user-supplied hardware. You may also use the brackets to secure the PDU to the underside of a counter with the addition of two user-supplied screws. Bolt-down retention brackets keep power cords organized and your rack free of clutter.Compatible with a Variety of Input Cords to Fit Your Facility’s Power SourceThe PDU’s C20 inlet accepts a variety of 16A international cordsets. An included 10-ft. (3.05 m) cord with NEMA L6-20P input plug connects to an AC power source, generator or protected UPS system to distribute power to connected loads.
by Schneider Electric NetShelter 40-Outlets PDU - Switched - NEMA L6-30P - 20 x IEC 60320 C13/C15, 20 x IEC 60320 C13/C15/C19/C21 - 230 V AC - 0U - Rack
CyberPower PDU44001 Switched ATS 10-Outlets PDU - Switched - NEMA 5-15P - 10 x NEMA 5-15R - 120 V AC - Network (RJ-45) - 1U - Horizontal - Rack-mountable
by Schneider Electric Metered-by-Outlet Rack PDU - Metered-by-Outlet - Rack-mountable - Tower
Eaton Tripp Lite Series 2.9kW Single-Phase 120V Basic PDU, 24 NEMA 5-15R Outlets, NEMA L5-30P Input, 15 ft. (4.57 m) Cord, 1U Rack-Mount - 24 x NEMA 5-15R - 24 - 1U 19" Rack-mountable
Product OverviewStreamline capacity planning and power management with the CyberPower PDU81102 switched metered-by-outlet PDU. Ideal for data centers and network closets, this unit provides outlet-level power monitoring in real time, along with individual outlet control for remote reboots, load shedding, controlled power-cycling and more. The PDU81102 supports inputs between 100-120V and includes 24 NEMA 5-20R outlets. Other features include a rack mount design (0U), built-in web interface (RJ-45 ethernet connection), interactive digital display and power event notifications. The CyberPower PDU81102 is protected by a three-year limited warranty.Power DistributionDelivers AC power to servers, equipment, and connected devices via a power distribution unit.Switch-Free DesignSafeguards against accidental power shut down.Switchable OutletsProvides local and remote control for individual and multiple outlets. Local control: turn on/turn off outlets and disable unused outlets. Remote control: restart outlets and devices, turn on/turn off, schedule power on/off sequencing, and disable unused outlets.Per Outlet Power MeteringProvides information on the amount of power being drawn from each outlet, each circuit and the PDU as a whole.CyberPower Management ConsoleA hardware interface built into Monitored and Switched PDUs. Its functionality includes the ability to switch PDU outlets on and off, reboot connected equipment locally or remotely, schedule power cycling of attached equipment, and perform other tasks, such as load monitoring and event loggingRemote and Local MonitoringEnables offsite and onsite tracking of PDU vitals; provides outlet control for individual and networked clients.Automatic Event NotificationsProvide immediate updates about power events via email, SMS text, or SNMP traps.Upgradeable FirmwareDownloadable improvements (firmware updates) to programs that run the PDU.Digital DisplayProvides easy-to-read information about amperage, voltage, KW, IP address, and other PDU information.Network-Grade Plugs and OutletsHighly durable construction ensures the efficient distribution of power in demanding IT or industrial environments to servers, equipment, and connected devices.Long Input Power CordReaches distant power sources, allowing the PDU to be placed where it’s needed.Cord Retention TraySecures power cords, keeping them organized and accessible. Helps cords stay plugged in.Durable Metal HousingProtects internal components and resists damage from impact or abrasions within challenging industrial environments. Also extends the life of the product.
Tripp Lite PDU 3-Phase Metered 208V 8.6kW L21-30P 36 C13; 9 C19 0URM TAA - Vertical Rackmount, Toolless-mount - RoHS, TAA Compliance