Tripp Lite PDUV20-72. PDU types: Basic, Rack capacity: 0U, Type: Single-phase. AC outlets quantity: 36 AC outlet(s), AC outlet types: NEMA 5–15, NEMA 5–20R, Power plug: NEMA L5-20P. Cable length: 179.9"" (4.57 m). Nominal input voltage: 100 - 127 V, Maximum current: 20 A, AC input frequency: 50 - 60 Hz. Width: 1.5"" (38.1 mm), Depth: 1.64"" (41.7 mm), Height: 72.5"" (1840.7 mm)
Vertiv Monitored rack PDUs (rPDU) provide a comprehensive view of power usage, both at the rack and via remote access while continuing to provide reliable power distribution to critical IT equipment. Monitored rPDUs are available in a variety of electrical and receptacle configurations. Every unit is 100% tested for reliability and functionality.
Vertiv Switched rack PDUs (rPDU) provide a comprehensive view of critical IT equipment power usage, both at the rack and via remote access with the added ability to remotely turn on, turn off, or reboot power at each outlet. Switched rPDUs are available in a variety of electrical and receptacle configurations. Every unit is 100% tested for reliability and functionality.
CyberPower Switched ATS PDU PDU44004 12-Outlets PDU - Switched - IEC 60320 C14 - 12 x IEC 60320 C13 - 230 V AC - Network (RJ-45) - 1U - Horizontal - Rack-mountable Ensure continued operation of critical devices with the CyberPower PDU44004 Switched ATS PDU. Ideal for data centers and network closets, this unit provides power redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable. Additionally, this unit offers real time remote and local monitoring and outlet management. The PDU44004 supports inputs between 200-240V and includes (12) IEC C13 outlets. Dual IEC C14 power cords are plugged into separate power sources (A and B), and information about each power source is clearly displayed on the front panel LED indicator lights. Other features include an LCD with selectable background color, built-in web interface, and power event notifications. The CyberPower PDU44004 is protected by a three-year limited warranty.
CyberPower PDU81105 Single Phase 200 - 240 VAC 30A Switched Metered-by-Outlet PDU - 24 Outlets, 10 ft, NEMA L6-30P, Vertical, 0U, LCD, 3YR Warranty Streamline capacity planning and power management with the CyberPower PDU81105 switched metered-by-outlet PDU. Ideal for data centers and network closets, this unit provides outlet-level power monitoring in real time, along with individual outlet control for remote reboots, load shedding, controlled power-cycling and more. The PDU81105 supports inputs between 200-240V and includes 21 C13 and 3 C19 outlets. Other features include a rack mount design (0U), built-in web interface (RJ-45 ethernet connection), interactive digital display and power event notifications. The CyberPower PDU81105 is protected by a three-year limited warranty.
Eaton Basic rack PDU, 0U, L6-30P input, 1.92 kW max, 200-240V, 16A, 10 ft cord, Single-phase, TAA compliant, Outlets: (24) C13 Outlet grip, (6) C19 Outlet grip Basic - NEMA L6-30P - 6 x IEC 60320 C19, 24 x IEC 60320 C13 - 36U - Rack-mountable
Description: APC Basic Rack PDU, Input : 120, 208, 230V , Input Connection Type : IEC-320 C20 , Cord Length : 8.2 feet ( 2.5 meters ) , Output : 120, 208, 230V , Output Connections : (10)IEC 320 C13, (2)IEC 320 C19 Features: 19 inch Rack-Mountable, Low Cost Power Distribution, Vertical Mounting Capabilities Includes: Cord Retention Clips, Rack Mounting Brackets, User Manual Output Voltage(s) (main only) - 120, 208, 230 V Maximum Total Current Draw per Phase - 16 A Output Connections - (10)IEC 320 C13; (2)IEC 320 C19 Always on Outlets - 12 Overload Protection Input: Nominal input voltage - 120, 208, 230 Input frequency (Hz) - 50/60 Hz Input Connection Type - IEC-320 C20 Cord Length 8.2 feet ( 2.5 meters ) Acceptable Input Voltage - 90-250 VAC Maximum Line Current per phase - 16.0 A Maximum Input Current per phase - 16.0 A Load Capacity - 3680
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA