Flat 5% Discount for Gov, Edu & Corporate clients.
Bypass PDU Recommended for Maintaining Continuous Power During UPS MaintenanceKeeping mission-critical data center equipment operating at its optimal level often means scheduledmaintenance. But what if you are unable to afford the costly downtime involved in powering down forregular upkeep? This 100-125V 12A single-phase hot-swap PDU works in conjunction with your UPSsystem to keep everything running 24/7/365. It allows you to manually transfer connected equipment toutility power via the PDU’s bypass switch, permitting maintenance or equipment replacement with nointerruption of performance.Features Dual Inputs and a Manual Transfer Switch for Uninterrupted OperationThe PDUB151U includes separate UPS and utility input cables with NEMA 5-15P plugs. The manualtransfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace theUPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipmentconnected to the six NEMA 5-15R outlets will continue to operate without interruption.Optional ECO Switching Feature Enables Cost-Cutting Power SavingsBy enabling the ECO power saving feature, you can power off a single bank of five controlled 5-15Routlets all at once when the device connected to the master 5-15R outlet is powered off or goes into a lowpower consumption mode. Mounts into 1U of Rack Space or WallUse the included mounting hardware to install the PDUB151U’s all-metal housing into 1U of space in anEIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall.
Bypass PDU Recommended for Maintaining Continuous Power During UPS MaintenanceKeeping mission-critical data center equipment operating at its optimal level often means scheduled maintenance. But what if you are unable to afford the costly downtime involved in powering down for regular upkeep? This 200–250V 16A single-phase hot-swap rack PDU (rPDU) works in conjunction with your UPS system to keep everything running 24/7/365. It allows you to manually transfer connected equipment to utility power via the PDU’s bypass switch, permitting maintenance or equipment replacement with no interruption of performance.Features Dual Inputs and a Manual Transfer Switch for Uninterrupted OperationThe PDUBHV201U features two C20 inlets that connect to separate UPS and utility input power sources with user-supplied power cables or the included C19-to-C20 cables. The manual transfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace the UPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipment connected to the outlets will continue to operate without interruption.Optional ECO Switching Feature Enables Cost-Cutting Power SavingsBy enabling the ECO power saving feature, you can power off a single bank of four controlled C13 outlets all at once when the devices connected to the master C13 and C19 outlets are powered off or go into a low-power consumption mode. Mounts into 1U of Rack Space or on a WallUse the included mounting hardware to install the PDUBHV201U’s all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall.
This Switched Automatic Transfer Switch / ATS PDU provides a redundant power option for single-corded network devices. Dual input cords support separate connection to primary and secondary power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. SmartOnline® series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separate) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
The PDUMNV20LX 1.9kW Single-Phase Monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via built-in network connection. Recommended for any IT or industrial application, it features 24 NEMA 5-15/20R outlets with included cord retention brackets to prevent cables from becoming accidentally disconnected. A 10-foot cord with NEMA L5-20P plug and 5-20P adapter connects the PDU to a compatible AC power source, generator or protected UPS.The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.A digital ammeter allows you to monitor the PDU's current level in real time to ensure it remains well below maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.Distributes Network-Grade Single-Phase Power- 1.9kW 120V 20A monitored PDU with single-phase input/output- NEMA L5-20P with 10 ft. cord connects to compatible AC power source- NEMA 5-20P adapter converts locking input plug to straight-blade plug- Firmware upgrades support future product enhancements24 Outlets Distribute AC Power- 24 NEMA 5-15/20R outlets- Cord retention bracket prevents cables from becoming accidentally disconnectedDigital Ammeter- Reports total connected equipment load- Supports IP-address self-ID- Rotates 180° for easy reading at either angleBuilt-In LX Platform Interface- Allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH- Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities- No Java requiredBroad Communications Compatibility- Supports HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP- Supports automatic and manual assignment of IP addressEasy 0U Installation in EIA-Standard 19 in. Racks- Mounts vertically using included toolless buttons or rack-mounting brackets- Included PDUMVROTATEBRKT allows mounting with rear-facing outletsTAA-CompliantCompliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
Tripp Lite single phase Metered PDU / Power Distribution Units offer real-time local reporting of load level in amps via built-in digital display. Enables visual monitoring of PDU load levels to prevent overloads as additional equipment is added. Offers reliable rackmount multi-outlet power distribution from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.- 20A single phase 120V Metered Power Distribution Unit / PDU (Agency de-rated to 16A continuous)- Two-digit lighted meter reports combined total output current in amps- Attached NEMA L5-20P input plug with 15ft / 4.6m line cord and 5-20P adapter- 0U 60in / 152cm vertical rackmount format installs using no rack spaces- 28 NEMA 5-15/20R outlets- Includes 20A circuit breaker and lighted power switch inside a transparent protective cover- Toolless installation supported in button-mount compatible equipment racks- Bolt-down installation brackets support installation in other racks and additional surfaces
Delivers 120V single-phase AC power to multiple loads while also protecting connected equipment from dangerous surges and spikes.Single-Phase 120V PDU Distributes and Monitors Network-Grade Power to Multiple LoadsThis local metered PDU is an ideal unit for telecom, security, audio/video and a wide variety of general portable and stationary rack-mount applications. Recommended for network-grade IT environments, the PDUMV20-ISO provides real-time monitoring of load levels via its built-in digital current metering. A 15-foot (4.6-meter) cord with L5-20P input plug (5-20P adapter included) connects to your facility’s AC power source, generator or protected UPS system to distribute power to connected loads.Digital Load Meter Helps Prevent Potentially Expensive OverloadsThe PDUMV20-ISO features 28 NEMA 5-15/20R outlets for delivering power to equipment. A digital ammeter reports the total input current in real time. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels can keep your TCO (total cost of ownership) low.3840 Joules per Load Bank Fight Back Against Unexpected Power SurgesProtecting your valuable electronics is ISOBAR® network-grade AC surge and noise suppression. A 3840-joule surge protection rating defends your sensitive electronic components against even the strongest power surges, spikes and line noise. The PDUMV20-ISO covers full normal (H-N) and common (N-G/H-G) protection modes. A green LED confirms your connected equipment is protected.Up-to-Date Safety Features Protect Your Vital EquipmentAll outlets are protected by a resettable 20A circuit breaker that shuts down the PDU in the event of a power load to safeguard connected equipment. A transparent cover protects the lighted on/off switch to help prevent an accidental shutdown that could lead to costly downtime.Versatile Installation Options Give You Plenty of ChoicesThe 0U PDU mounts vertically using the included hardware. Vertical 0U mounting reduces cable clutter and permits efficient airflow through the rack. You can also install the long-lasting all-metal housing on a wall, raceway or a similar flat surface.
Tripp Lite PDU Switched 1.9kW 120V 24 5-15/20R 20A LX Platform 0URM TAA - Switched - NEMA L5-20P/5-20P - 24 x NEMA 5-15/20R - 120 V AC - Network (RJ-45) - 0U - Vertical - Rack Mount - TAA Compliant - TAA Compliance
Tripp Lite by Eaton PDU 5.8kW Single-Phase Local Metered PDU 200-240V Outlets (8 C19 and 40 C13) L6-30P 10 ft. (3.05 m) Cord 0U Vertical TAA 70 in. NEMA L6-30P - 8 x IEC 60320 C19, 40 x IEC 60320 C13
by Schneider Electric Smart-UPS SRT 6kVA PDU 208V (4) L6-20 & (1) L6-30 - 1 x NEMA L6-30R, 4 x NEMA L6-20R - 230 V AC - 6000 W - Tower
Upgradeable Unit Level EC Monitored rPDUs provide reliable power distribution to critical IT equipment while delivering a comprehensive view of input level power usage via remote network access. Includes environmental monitoring capabilities to obtain real-time environmental metrics. Upgrade the hot-swappable monitoring device on select units to leverage new technologies and accommodate changing business needs.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA