Tripp Lite Metered PDU / Power Distribution Units offer real-time local reporting of load level in amps via built-in digital meter. Enables visual current monitoring of PDU output current to prevent circuit overloads as additional equipment is added. Offers reliable rackmount multi-outlet power distribution from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.- 20A single phase 120V Metered Power Distribution Unit / PDU (Agency de-rated to 16A continuous)- Built-in 2 digit visual meter continuously reports PDU load level in amps- Attached NEMA L5-20P 20A 120V input plug with 15 ft. / 4.5m line cord- Includes 5-20P 20A 120V plug adapter- 1U horizontal rackmount format installs in one rack space- 12 NEMA 5-15/20R outlets- Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formats- Mounting ears are reversible for front or rear facing rackmount installation- Optional PDUSIDEBRKT enables 0U vertical rackmount in compatible racks- Back panel grounding lug
Tripp Lite PDU Switched ATS 2/2.4KW 200/240V 10 C13 2 C14 3.6M Cords 1URM - IEC 60320 C14 - 10 x IEC 60320 C13 - 200 V AC, 208 V AC, 220 V AC, 230 V AC, 240 V AC - 2.40 kVA - Network (RJ-45) - 1U/2U - Horizontal Rackmount
Single-Phase PDU Distributes and Monitors Network-Grade Power in Real TimeThis metered PDU provides real-time local reporting of the total load level via its built-in digital currentmetering. Ideal for network IT applications, small computer rooms and other equipment rack applications,the PDUMH20HVL66 features eight C13 and two C19 208/230V outlets for connecting equipment. Pluglock insert sleeves are included to prevent connected cables from becoming accidentally dislodged.Digital Load Meter Helps Prevent Potentially Expensive OverloadsA digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensureload levels remain well below maximum capacity with no danger of overload that could lead to costlydowntime or damaged equipment. Maintaining proper load levels, even while adding new equipment, cankeep your TCO (total cost of ownership) low.Versatile Installation Options Give You Plenty of ChoicesThe reversible all-metal housing comes with mounting brackets for installation in 1U of space or 0Uvertical mounting in an EIA-standard 19-inch rack. You can also reorient the brackets for permanentmounting under a counter or on a wall with user-supplied hardware. The six-foot cord with NEMA L6-20Pinput plug connects the single-phase PDU to a protected UPS system, generator or mains input source forreliable multi-outlet power distribution.TAA-Compliant for GSA Schedule PurchasesThe PDUMH20HVL66 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligiblefor GSA (General Services Administration) Schedule and other federal procurement contracts.
Tripp Lite PDU 3-Phase Metered 208V 8.6kW L21-30P 36 C13; 9 C19 0URM TAA - Vertical Rackmount, Toolless-mount - RoHS, TAA Compliance
Tripp Lite Basic Power Distribution Units / PDU systems offer reliable rackmount power distribution for critical IT equipment in wiring closets, server rooms and equipment racks. Supplies continuous power from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.- 30A single phase 120V Basic Power Distribution Unit / PDU (Agency de-rated to 24A continuous)- Attached NEMA L5-30P 30A 120V input plug with 15 ft. / 4.5m line cord- 1U horizontal rackmount format installs in one rack space- 24 NEMA 5-15R outlets (12 front / 12 rear)- Adjustable mounting brackets enable installation in 2 or 4 post racks, plus additional support for wallmount and under-counter mounting- Optional PDUSIDEBRKT enables 0U vertical rackmount in compatible racks- Mounting ears are reversible for front or rear facing rackmount installation- Back panel grounding lug
The PDUMV40 provides an efficient and manageable power distribution solution for multiple servers with dual redundant power supplies, or any other application that requires numerous outlets, high capacity, and a compact form factor. Dual input current monitoring display shows AC power consumption for each independent circuit. Switchless design eliminates accidental shutoff of connected equipment. Unfiltered electrical pass-through without a power switch makes the PDUMV40 ideal for distributing alternate waveform UPS or generator power in rack enclosures, network closets, and more. Each of two independent circuits' supports 16 outlets and equipment loads up to 2,400 watts32 outlets and 4,800 watts total capacity without consuming additional rack space.- All-in-one Zero U form factor enables efficient, single-enclosure installations- Dual independent circuit design delivers high capacity across 32 outlets in minimal space- Input plugs, input power cords, breakers and outlets are color-coded to match each independent 20A circuit, allowing simplified cable management for multi-server configurations (each circuit is Agency de-rated to 16A continuous)- Dual digital current monitoring displays (1 for each circuit)- 10 ft. dual input power cords increase mounting flexibility; mounting hardware included- Combines the advantages of two separate high-current PDU's without the extra expense, increased space requirements and added management complexity- Includes two adapters that convert NEMA L5-20P input plugs to NEMA 5-20P. Twist-lock interface ensures secure connection- Switchless design prevents accidental shutdown of connected equipment- Toolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications
Eaton 5.5kW Single-Phase Monitored PDU with LX Platform Interface, 208/230V Outlets (12-C13 and 4-C19), L6-30P, 12 ft. (3.66 m) Cord, 2U Rack-Mount, TAA 4 x IEC 60320 C19, 12 x IEC 60320 C13 - 2U - Horizontal Rackmount"
Bypass PDU Recommended for Maintaining Continuous Power During UPS MaintenanceKeeping mission-critical data center equipment operating at its optimal level often means scheduledmaintenance. But what if you are unable to afford the costly downtime involved in powering down forregular upkeep? This 120V 20A single-phase hot-swap PDU works in conjunction with your UPS systemto keep everything running 24/7/365. It allows you to manually transfer connected equipment to utilitypower via the PDU’s bypass switch, permitting maintenance or equipment replacement with nointerruption of performance.Features Dual Inputs and a Manual Transfer Switch for Uninterrupted OperationThe PDUB201U includes separate UPS and utility input cables with NEMA 5-20P plugs. The manualtransfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace theUPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipmentconnected to the six NEMA 5-20R outlets will continue to operate without interruption.Optional ECO Switching Feature Enables Cost-Cutting Power SavingsBy enabling the ECO power saving feature, you can power off a single bank of five controlled 5-20Routlets all at once when the device connected to the master 5-20R outlet is powered off or goes into a lowpower consumption mode.Mounts into 1U of Rack Space or WallUse the included mounting hardware to install the PDUB201U’s all-metal housing into 1U of space in anEIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall.
Tripp Lite PDUH20-ISO. PDU types: Basic, Rack capacity: 0U/1U, Type: Single-phase. AC outlets quantity: 14 AC outlet(s), AC outlet types: NEMA 5–15R, NEMA 5–20R, Power plug: NEMA L5-20P. Cable length: 179.9"" (4.57 m). Nominal input voltage: 100 - 127 V, Maximum current: 20 A, AC input frequency: 50 - 60 Hz. Width: 20"" (508 mm), Depth: 4.5"" (114.3 mm), Height: 2"" (50.8 mm)
Tripp Lite by Eaton PDU 5.8kW Single-Phase Local Metered PDU 200-240V Outlets (8 C19 and 40 C13) L6-30P 10 ft. (3.05 m) Cord 0U Vertical TAA 70 in. NEMA L6-30P - 8 x IEC 60320 C19, 40 x IEC 60320 C13