Tripp Lite SU16KRTG 16,000VA / 16kVA / 14,400 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 12U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 8kVA, and non-redundant operation at loads between 8 and 16kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.Tripp Lite SU16KRTG 16kVA, 16,000VA / 14,400 watt on-line, double-conversion UPS system in 12U total rack/tower configurationUnique configuration offers 16kVA non-redundant operation and automatic N+1 redundancy at load levels of 8kVA and underIncluded Parallel PDU with manual bypass switch enables hot-swap replacement power modules at any supported load levelHardwire input; 8 C19 outletsMaintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominalSupports 50/60Hz operation for worldwide frequency compatibilityCompatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD and RELAYIOCARD (NOTE: Applications utilizing any supported network management card option, require the installation of two of the same model network card – install one card per included UPS power module)Optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilitiesPADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurationsExpandable runtime with optional external battery packsSome external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)Battery independent restartIntelligent battery management system with temperature-compensated charging extends battery lifeHID-compliant USB interfaceUSB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralertOptional 2POSTRMKITHD supports installation in 2 post 19 inch racks (4 required)Optional 2-9USTAND supports upright tower placement (2 required)Supports Emergency Power Off (EPO) via built-in interfaceFront panel LEDs and LCD readout with scroll controlsLED / LCD display panel rotates for viewing in rackmount or tower configurationsExternal battery packs are field replaceable and hot swappableFrequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
Tripp Lite SU16KRT-1TF 16,000VA / 16kVA / 14,400 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 14U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 8kVA, and non-redundant operation at loads between 8 and 16kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.- Tripp Lite SU16KRT 16kVA, 16,000VA / 14,400 watt on-line, double-conversion UPS system in 14U total rack/tower configuration- Unique configuration offers 16kVA non-redundant operation and automatic N+1 redundancy at load levels of 8kVA and under- Included Parallel PDU with manual bypass switch enables hot-swap replacement of power modules at any supported load level- Hardwire input; 2 L6-30R (208/240v), 8 C19 (208/240v), 8 5-15/20R (120v) and 4 5-15R (120v) outlets- Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V & 120V nominal- Expandable runtime with optional external battery packs- Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)- Battery independent restart- Highly efficient economy mode option- Optional SNMPWEBCARD, RELAYIOCARD and RELAYIOMINI interface modules available (RELAYIOMINI requires removal of USB interface module)- Applications utilizing the optional network communications card require two SNMPWEBCARD accessories (install one per included power module)- HID-compliant USB interface- Includes Free PowerAlert monitoring software; PowerAlert LOCAL, PowerAlert NSA and PowerAlert NMS for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices- Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (6 required)- Optional 2-9USTAND supports upright tower placement (2 required)- Supports Emergency Power Off (EPO) via built-in interface- Front panel LEDs and LCD readout with scroll controls- LED / LCD display panel rotates for viewing in rackmount or tower configurations- External battery packs are field replaceable and hot swappable
Tripp Lite SU20KRT-1TF 20,000VA / 20kVA / 18,000 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 14U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 10kVA, and non-redundant operation at loads between 10 and 20kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.- Tripp Lite SU20KRT-1TF 20kVA, 20,000VA / 18,000 watt on-line, double-conversion UPS system in 14U total rack/tower configuration- Offers enhanced fault-tolerance and reliability with N+1 configuration support and hot-swappable whole UPS replacement options- Unique configuration ties input, output and data connections of two standard 10kVA UPS systems via detachable parallel PDU to offer 20kVA non-redundant operation and automatic N+1 redundancy at load levels of 10kVA and lower- Included Parallel PDU with manual bypass switching enables hot-swappable replacement of either 10kVA power module at any supported load level, with no interruption to connected equipment- Hardwire input; 2 L6-30R (208/240v), 8 C19 (208/240v), 8 5-15/20R (120v) and 4 5-15R (120v) outlets- Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions- Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise- Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types- Maintains full-time sine wave output within 2% of selectable 208/240 and 120V nominal at 60Hz during brownouts as low 100V and overvoltages as high as 300V- Expandable runtime is supported with optional BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH; BP240V1037C-1PH; BP240V1407C-1PH external battery packs- Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs- Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement- Rack / tower configuration installs in 14 total rack spaces (14U) with a maximum installed depth of only 32.5 in. / 82.6 cm- PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted- Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA (Network Shutdown Agent) for larger networks and PowerAlert NMS (Network Management System) for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices- Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232 and USB interfaces- HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X- Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces- Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification- Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module)- Supports Emergency Power Off (EPO) via built-in interface- Included rail kit supports 14U 19 inch rackmount installation in 4 post racks- Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (5 required for SU20KRT-1TF)- Optional 2-9USTAND supports upright tower placement (2 required for SU20KRT-1TF)- Front panel LEDs and LCD readout with scroll controls and password option supports visual monitoring of all major UPS functions and advanced UPS settings for charge level, nominal voltage selection, frequency conversion and other operational parameters- LED / LCD display panel rotates for viewing in rackmount or tower configurations- Network-grade AC surge and noise suppression- Industrial mode option (factory preset) enables supports high current startup loads by momentarily switching to bypass mode in response to short duration overload conditions- Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (output de-rates by 25%)- External battery packs are field replaceable and hot swappable
Tripp Lite SU20KRTG 20,000VA / 20kVA / 18,000 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 12U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 10kVA, and non-redundant operation at loads between 10 and 20kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.Tripp Lite SU20KRTG 20kVA, 20,000VA / 18,000 watt on-line, double-conversion UPS system in 12U total rack/tower configurationUnique configuration offers 20kVA non-redundant operation and automatic N+1 redundancy at load levels of 10kVA and underIncluded Parallel PDU with manual bypass switch enables hot-swap replacement power modules at any supported load levelHardwire input; 8 C19 outletsMaintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominalSupports 50/60Hz operation for worldwide frequency compatibilityCompatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD and RELAYIOCARD (NOTE: Applications utilizing any supported network management card option, require the installation of two of the same model network card – install one card per included UPS power module)Optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilitiesPADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurationsExpandable runtime with optional external battery packsSome external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)Battery independent restart ensures automatic UPS power-up after lengthy power outages, even with expired batteriesIntelligent battery management system with temperature-compensated charging extends battery lifeHID-compliant USB interfaceUSB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralertOptional 2POSTRMKITHD supports installation in 2 post 19 inch racks (4 required)Optional 2-9USTAND supports upright tower placement (2 required)Supports Emergency Power Off (EPO) via built-in interfaceFront panel LEDs and LCD readout with scroll controlsLED / LCD display panel rotates for viewing in rackmount or tower configurationsExternal battery packs are field replaceable and hot swappableFrequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
12V DC, 36-Amp Replacement Battery for HCRK-36 Medical-Grade Mobile Power Retrofit Kit. Sealed lead acid, maintenance-free, spill/leak proof, AGM battery, simple plug-in connection with included cable – Included in the HCRK-36. This is the replacement battery for the HCRK-36 battery.
The OMNIX350HG offers medical-grade UPS protection with built-in line-interactive voltage regulation. IEC320 plug and outlets, plus built-in isolation transformer with Faraday shield offer full isolation and remove common mode noise. Tested to CE/IEC 60601-1 as medical electrical equipment. 350VA power handling capacity supports computers, inter-networking equipment and other critical loads during commercial power failures. Line-interactive voltage regulation corrects brownouts as low as 159V back to normal 230V levels, saving battery reserves for use only during complete power failures. Includes two-line phone surge suppression and built-in USB communications port.This UPS contains a lead acid battery designed to be connected continuously to an AC power source, except during brief power outages. It is not intended for frequent charge/discharge cycles, such as mobile cart applications where the UPS is often disconnected from the power source. Using the OMNIX350HG in this type of application will void the battery warranty.
Tripp Lite 3 phase Monitored PDU / Power Distribution Unit offers real-time remote monitoring of voltage, frequency and load levels via built-in network connection. PowerAlert interface supports custom notification of user-specified remote conditions via email, secure web, SNMP, Telnet or SSH interface. PDU output current consumption in amps is displayed per-phase via front panel lighted digital display and can be monitored remotely to warn of potential overloads before critical IT mains breakers trip.- 8.6kW 3 phase 208V Monitored Power Distribution Unit / PDU with built-in web/network interface- Attached IEC-309 Blue 30A (3P+E) 208V 3 phase input plug with 3 ft. / 1m cord- 0U, 70 in. / 178cm vertical form factor supports installation in 2 or 4 post equipment racks- 36 total 208V outlets (30 C13, 6 C19) arranged in three breakered single phase output load banks- Lighted display with scroll-button reports power consumption in amps for all 3 loading banks, IP-address self-identification and 180 degree display rotation for overhead or raised floor power feeds- Built-in SNMP/ethernet interface reports voltage, frequency and PDU loading per-phase via network or secure web browser interface with options for user specified alarm and notification thresholds- Supports in-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors- DHCP/Manual configuration support- 10/100 Mbps auto-sensing allows optimal communication with 10/100 Base-T networks- Real-time clock backup maintains the time of day and date even if the PDU is unpowered- Tiered access privileges allow an administrator and a guest to login via web browser for monitoring- Alert notifications via email or SNMP traps offer immediate event notification- Firmware upgrade ability supports future product enhancements- Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols- Fully compatible with FREE PowerAlert Network Management System / NMS Software- Included cord retention brackets keep vital network equipment plugged in and continuously powered- Toolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications
Tripp Lite 3 phase Monitored PDU / Power Distribution Unit offers real-time remote monitoring of voltage, frequency and load levels via built-in network connection. PowerAlert interface supports custom notification of user-specified remote conditions via email, secure web, SNMP, Telnet or SSH interface. PDU output current consumption in amps is displayed per-phase via front panel lighted digital display and can be monitored remotely to warn of potential overloads before critical IT mains breakers trip.- 5.7kW 3 phase 208V Monitored Power Distribution Unit / PDU with built-in web/network interface- Attached NEMA L21-20P 20A (3P+N+E) 208V 3 phase input plug with 10 ft. / 3m cord- 0U, 70 in. / 178cm vertical form factor supports installation in 2 or 4 post equipment racks- 36 total 120V NEMA 5-15/20R outlets arranged in three breakered single phase output load banks- Lighted display with scroll-button reports power consumption in amps for all 3 loading banks, IP-address self-identification and 180 degree display rotation for overhead or raised floor power feeds- Built-in SNMP/ethernet interface reports voltage, frequency and PDU loading per-phase via network or secure web browser interface with options for user specified alarm and notification thresholds- Supports in-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors- DHCP/Manual configuration support- 10/100 Mbps auto-sensing allows optimal communication with 10/100 Base-T networks- Real-time clock backup maintains the time of day and date even if the PDU is unpowered- Tiered access privileges allow an administrator and a guest to login via web browser for monitoring- Alert notifications via email or SNMP traps offer immediate event notification- Firmware upgrade ability supports future product enhancements- Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols- Fully compatible with FREE PowerAlert Network Management System / NMS Software- Included cord retention brackets keep vital network equipment plugged in and continuously powered- Toolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications
This Switched PDU offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption. Built-in LX Platform network management interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. Individually switched outlets can be controlled in real time to remotely reboot unresponsive network hardware or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps is displayed locally via front panel current meter or remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip.
3-Phase Metered PDU, 5.7 kW, 27 outlets (21 5-15/20R, 6 L6-20R), 208/120V output, 6 ft NEMA L21-20P input connection- Metered 5.7kW 3 Phase 208/120V PDU; 70 in. / 178cm 0U vertical rackmount- Reports input current per-phase via built in current meters- NEMA L21-20P (3P+N+E) 208V 3 phase input; 6 ft. / 1.8m line cord- 27 outlets total; 21 5-15/20R (120V), 6 L6-20R (208V)- Toolless button-mount installation; cord retention brackets includedTripp Lite 3 phase Metered PDU / Power Distribution Units offer real-time local reporting of current levels in amps via set of 3 built-in digital meters. Enables visual monitoring of PDU current levels to preserve proper loading balance and prevent circuit overloads as additional equipment is added. Offers reliable rackmount multi-outlet power distribution from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA