This single-phase Local Metered PDU offers real-time local reporting of load level in amps via built-in digital display. Enables visual monitoring of PDU load levels to prevent overloads as additional equipment is added. Offers reliable rack-mount multi-outlet power distribution from any protected UPS, generator or mains input power source. High-quality design includes rugged all-metal housing and secure rack-mount installation with included mounting accessories.
3.7kW 16A single phase 208/230V Local Metered Power Distribution Unit / rack PDU (rPDU)Built-in 2 digit visual meter continuously reports PDU load level in ampsC20 inlet with IEC-309 Blue 16A input; 2.5m line cord1U horizontal rackmount format installs in one rack space10 total outlets (8 C13 / 2 C19)Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formatsMounting ears are reversible for front or rear facing rackmount installationFront panel grounding lugCompliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
The APSX4048SW 4000W APS X Series 48V DC 220/230/240V AC Inverter/Charger is a reliable power source for a wide variety of tools and sensitive electronics at mobile, emergency and remote sites. With no fumes, fuel or excess noise, it's an excellent alternative to generator power. It's operable in single-phase mode or three-phase mode for high-capacity industrial and commercial installations.The DC-to-AC pure sine-wave inverter delivers network-grade power. Its automatic line-to-battery transfer switch and integrated charging system allow the unit to work as an extended-run UPS, standalone AC power source or vehicle inverter. It delivers 4000W of continuous power, 6000W up to one minute or 8000W of peak power up to 10 seconds during equipment startup or cycling. An automatic overload detector, cooling fan and resettable AC circuit breakers protect the unit from damage.Designed for easy installation in RVs, commercial and fleet vehicles and emergency vehicles, the APSX4048SW converts stored power from any 48V battery or automotive DC source to safe, stable, computer-grade AC power for unlimited runtime. When hardwired to an external AC source, the unit keeps the user-supplied batteries charged via a three-stage 1-70A selectable charging system while simultaneously delivering AC power to connected equipment. When used as a UPS, the APSX4048SW responds to blackouts and brownouts with an automatic, instantaneous transfer to battery-derived AC output.
Tripp Lite PDU3V20D354A. PDU types: Basic, Rack capacity: 0U, Mounting: Vertical. AC outlets quantity: 54 AC outlet(s), AC outlet types: C13 coupler, C19 coupler. Cable length: 29.9"" (0.76 m), Certification: Tested to UL60950-1 (USA), CSA (Canada), NOM (Mexico), FCC Class A (Emissions), ROHS. Nominal input voltage: 200-240 V, Maximum current: 35 A, AC input frequency: 50 - 60 Hz. Width: 2.2"" (55.9 mm), Depth: 2.22"" (56.4 mm), Dimensions (WxDxH): 2.2 x 2.22 x 70"" (55.9 x 56.4 x 1778 mm)
The PDUMNH16HVAT 3.8kW Single-Phase 200-240V Monitored Automatic Transfer Switch / ATS PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and has an IEC309 16A Blue outlet for connecting a single device or a 0U 230V vertical PDU with IEC309 16A Blue plug.Dual 10-ft. (3.05 m) input cords with IEC309 16A Blue plugs connect to separate primary and secondary single-phase power sources, including out-of-phase sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds if the primary source fails or becomes unstable to ensure connected equipment remains powered.Built-in LX Platform network management interface. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separate) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. Digital display with LEDs indicates power availability, voltage, input status for both power sources, output load and power factor, as well as temperature and humidity conditions with optional ENVIROSENSE2 module (sold separate).
High-capacity 3.3/3.8kW PDU with ATS provides remote power monitoring and enables redundant power for non-redundant hardware. Digital display and Ethernet interface monitor load levels to prevent overloads that cause downtime.- Two single-phase L6-20P inputs with 10 ft. cords- L6-20R outlet for connecting single device or 0U vertical PDU- Automatic transfer switching within 1–5 ms- Ethernet network interface for remote access- Digital display for real-time status monitoringThe PDUMNH20HVAT 3.3/3.8kW Single-Phase 208/240V ATS/Monitored PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and features one L6-20R outlet—perfect for connecting a single device or a 0U 208/240V PDU with an L6-20P plug. Dual 10-foot input cords with L6-20P plugs connect to separate primary and secondary single-phase power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption. Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP. Provides real-time load/current data with billing-grade accuracy (+/- 1 percent). Tiered access privileges allow both an administrator and a guest to log in. Automated alerts help prevent accidental overloads, power loss and downtime. Digital display indicates power availability, voltage, source A/B input status, output load and power factor, as well as temperature and humidity conditions with the optional ENVIROSENSE module (sold separately).Primary and Secondary Inputs for Power Redundancy- Provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations- Dual 10 ft. input cords with L6-20P plugs connect to separate primary and secondary single-phase power sources- Fault-tolerant, hot-swappable UPS protection when used with single UPS; fully redundant UPS protection when each cord is connected to separate UPS systemsBuilt-In L6-20R OutletConnects a single device or indirectly powers equipment through a 0U 208/240V PDU with L6-20P input (sold separately)Automatic Transfer Switching (ATS)- Dynamic solid-state (TRIAC) automatic transfer switching- Switches to secondary power source if primary source fails or becomes unstable- 1–5 ms transfer time ensures uninterrupted operation of connected equipment- Built-in processor prevents switching if secondary source is unavailable or of lower quality than primary sourceMultifunction Digital Display- Reports source A and source B input power status and other information, including power availability, line voltage, frequency, amps, kilowatts and power factorAdvanced Network Monitoring- Built-in Ethernet network interface allows full remote access for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP- Real-time load/current data with billing-grade accuracy (+/- 1 percent)- Automated alerts help prevent overloads, power loss and downtime- Optional ENVIROSENSE module (sold separately) monitors temperature and humidityBroad Communications Compatibility- Supports HTTP, HTTPS, PowerAlert®, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP and NTP- 10/100 Mbps auto-sensing allows optimal communication with 10/100 Base-T networksMounts Horizontally in 1U of Rack Space- Compatible with EIA-standard 19 in. 4-post racks and rack enclosures- Optional PDU4PKIT rail kit (sold separately) adds rear mounting support
Tripp Lite SmartPro 1050. Output power capacity: 1.05 kVA, Output power: 702 W, Surge energy rating: 480 J. Product color: Black. Weight: 29.1 lbs (13.2 kg). Output connections: 6 x NEMA 5-15R, Input connection type: NEMA 5-15P, Dimensions (WxDxH): 7.24 x 7.24 x 11.7"" (184 x 184 x 298 mm)
Tripp Lite VS650T. UPS topology: Line-Interactive, Output power capacity: 0.65 kVA, Output power: 360 W. AC outlet types: NEMA 5-15R, Power plug: NEMA 5-15P, AC outlets quantity: 6 AC outlet(s). Form factor: Tower, Product color: Black, Cable length: 59.1"" (1.5 m). Width: 4"" (101.6 mm), Depth: 11.8"" (299.7 mm), Height: 5.6"" (142.2 mm). Master (outer) case width: 14.2"" (360.7 mm), Master (outer) case length: 23.6"" (599.4 mm), Master (outer) case height: 9.8"" (248.9 mm)
UPS Replacement Battery Cartridge for Select UPS SystemsThis UPS backup battery replacement is designed for these specific battery-door enabled versions of AVR550U, AVRX550U, ECO550UPS, ECO650UM, INTERNET550SER, INTERNET550U and INTERNET600U that originally shipped with a 12V 3.6Ah battery inside. It is carefully screened and certified to meet or exceed original runtime specifications. The leakproof, no-maintenance RBC36H comes ready for quick and easy installation in your UPS system. It functions within a wide range of operating temperatures. Reusable packaging allows you to easily send expired batteries to a recycling center.
Tripp Lite Portable Power Stations Battery - For Notebook, Computer - Lithium Iron Phosphate (LiFePO4) - 2 A - 12 V DC Output - 5 V, 9 V Input - 3 - TAA Compliance
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA