APC by Schneider Electric Switched Rack PDU - Switched - NEMA 5-15P - 8 x NEMA 5-15R - 120 V - 1440 W - 0U - Rack-mountable - Tower - TAA Compliance
APC by Schneider Electric Rack PDU, Switched, 2U, 30A, 208V, (16)C13 - Switched - NEMA L6-30P - 16 x IEC 60320 C13 - 230 V - 6.50 ft Cord Length - 2U - Rack-mountable - TAA Compliance
by Schneider Electric NetShelter 42-Outlets PDU - Switched - IEC 60309 60A (3P+PE) - 21 x IEC 60320 C13/C15, 21 x IEC 60320 C13/C15/C19/C21 - 230 V AC - 0U - Rack
Eaton Basic Rack PDU HotSwap MBP 1U 110-125V 12A 1.44 kW NEMA 5-15P and 6 5-15R - 6 x NEMA 5-15R - 1.44kVA - 2U
APC AP8870 Rack Mount PDU, Metered 208V/30A, (28) Outlets, 0U Vertical Rackmount
APC by Schneider Electric Rack PDU 2G, Metered, ZeroU, 10.0kW, 208V, (36) C13 & (6) C19 Metered - CS8365 - 36 x IEC 60320 C13, 6 x IEC 60320 C19 - 208 V - 10 kW - Overload Protection - 6 ft Cord Length - 0U - Rack-mountable
APC NetShelter Rack PDU Advanced, Switched, 14.4kW, 3PH, 208V, 50A, CS8365C, 42 OutletAPC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2"" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.