AgilityWide range of input and output connectionsProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.Single input power sourceSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.Rack-MountableIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.Total Cost of OwnershipLow Cost Power DistributionProvides a number of outlets to bring power to rack equipment at an affordable price.Marketing FeaturesWide range of input and output connectionsProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.Single input power sourceSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.Rack-MountableIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.Low Cost Power DistributionProvides a number of outlets to bring power to rack equipment at an affordable price.
APC AP8867 Rack PDU 2G, Metered, ZeroU, 17.2kW, 208V, (30) C13 - 30 x IEC 60320 C13 - 17.20 kVARack-mountable - REACH, RoHS Compliance
APC Basic Rack 2880VA PDU - 24 x NEMA 5-20R - 2880VA - Zero U Rack-mountable - TAA Compliance
Tripp Lite PDU Monitored 208/240V 30A 36 C13; 6 C19 L6-30P LX Interface 0U - Monitored - NEMA L6-30P - 6 x IEC 60320 C19, 36 x IEC 60320 C13 - 230 V AC - 0U - Vertical - Rack Mount - Rack-mountable - TAA Compliant - TAA Compliance
16/20A single phase 208/230V Local Metered Power Distribution Unit / rack PDU (rPDU) (Agency de-rated to 16A continuous)Built-in 2 digit visual meter continuously reports PDU load level in ampsC20 inlet with C20 input cable and L6-20P adapter; 12-ft. (3.66 m) line cord1U horizontal rackmount format installs in one rack space10 total outlets (8 C13 / 2 C19)Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formatsMounting ears are reversible for front or rear facing rackmount installationOptional PDUSIDEBRKT enables 0U vertical rackmount in compatible racksBack panel grounding lugFederal Trade Agreements Act / TAA Compliant for GSA Schedule purchases
APC by Schneider Electric Rack PDU, Switched, 1U, 20A, 120V, (8)5-20 - Switched - NEMA L5-20P - 8 x NEMA 5-20R - 120 V - 2400 W - Network (RJ-45) - 1U - Rack-mountable - TAA Compliance
APC by Schneider Electric Rack PDU, Metered, 1U, 15A, 100/120V, (8) 5-15 - Metered - NEMA 5-15P - 8 x NEMA 5-15R - 120 V AC - 1U - Rack-mountable
APC by Schneider Electric Metered Rack AP8865 44-Outlets PDU - Metered - NEMA L21-30P - 0U - Rack-mountable - TAA Compliance
Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A, 208V, (21) C13 & (3) C19APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.Includes : CAN Port Terminator , Installation guide , Locking input power cord , Rack Mounting brackets , Safety guide , Serial configuration cableMetering-by-Outlet capabilityIndividual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning.Availability- Remote Individual Outlet ControlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).- Metering-by-Outlet capabilityIndividual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning.- Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)- Power DelaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.- Local Current Monitoring DisplayThe aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)- Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits. (Note: Only available with units with local current monitoring feature)- Flash UpgradeableQuickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)- Network Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.- Integrates with StruxureWare Data Center ExpertAn IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the networkAgility- Single input power sourceSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA