Tripp Lite PDUNVR30HVLX. PDU types: Monitored, Rack capacity: 0U, Type: Single-phase. AC outlets quantity: 24 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: NEMA L6-30P. Cable length: 120.1"" (3.05 m), Certification: TAA. Nominal input voltage: 200 - 240 V, Maximum current: 30 A, AC input frequency: 50 - 60 Hz. Width: 2.2"" (55.9 mm), Depth: 2.6"" (66 mm), Height: 70"" (1778 mm)
Single-Phase 15A ATS PDU Distributes and Monitors Network-Grade Power in Real TimeThis metered PDU provides real-time local reporting of the total load level via its built-in digital current metering. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMH15ATS features eight NEMA 5-15R 120V outlets for connecting equipment. Dual 12-foot (3.7-meter) power cords with NEMA 5-15P inputs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources.Switches from Primary to Secondary Power Source in MillisecondsAutomatic transfer switching (ATS) allows the PDU to switch to the secondary source within 2–7 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source.Digital Load Meter Helps Prevent Potentially Expensive OverloadsA digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low.Mounts into 1U of Rack Space or on a WallUse the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall or under a counter.TAA-Compliant for GSA Schedule PurchasesThe PDUMH15ATS is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
32A 7.4kW single phase 230V Monitored Power Distribution Unit / rack PDU (rPDU)Attached Blue IEC-309 32A (2P+E) input plug with 3.65m line cord2U horizontal rackmount format16 outlets (12 C13, 4 C19)Lighted display with select button reports output power consumption in amps in 3 segments (bank 1, bank 2 and total)Pre-installed WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilitiesPADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurationsOptional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilitiesDHCP/Manual configuration support10/100 Mbps auto-sensing allows optimal communication with 10/100 Base-T networksReal-time clock backup maintains the time of day and date even if the PDU is unpoweredTiered access privileges allow an administrator and a guest to login via web browser for monitoringAlert notifications via email or SNMP traps offer immediate event notificationMounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formatsMounting ears are reversible for front or rear facing rackmount installationIncluded cord retention brackets keep vital network equipment plugged in and continuously poweredFederal Trade Agreements Act / TAA Compliant for GSA Schedule purchases
16/20A 230/208V Monitored Power Distribution Unit / rack PDU (rPDU) (agency derated to 16A continuous)C20 inlet; 8ft / 2.4m C20 cable and NEMA L6-20P plug adapter included1U horizontal rackmount installation8 C13 outletsLighted display reports output power consumption in ampsBuilt-in network interface reports voltage, frequency and PDU loading via network or secure web browser interface with options for user specified alarm and notification thresholdsPre-installed WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilitiesPADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurationsOptional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities10/100 Mbps auto-sensing allows optimal communication with 10/100 Base-T networksReal-time clock backup maintains the time of day and date even if the PDU is unpoweredTiered access privileges allow an administrator and a guest to login via web browser for monitoringAlert notifications via email or SNMP traps offer immediate event notificationFirmware upgrade ability supports future product enhancements.Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formatsMounting ears are reversible for front or rear facing rackmount installationIncluded cord retention brackets keep vital network equipment plugged in and continuously poweredTAA Compliant for GSA Schedule purchases
Tripp Lite Metered ATS / Auto Transfer Switch PDU systems enable redundant power configurations for network devices with a single input cord connection. Set of two ATS inputs support connection to separate PRIMARY and SECONDARY power sources. The ATS normally maintains continuous output to connected equipment derived from the primary input. If the primary input fails or becomes unstable, the ATS will switch over to the secondary power source until the primary input is restored and stable. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources to support a variety of advanced redundant power networking applications. Enables fault-tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time, similar to Tripp Lite SmartOnline series. ATS configurations utilizing separate mains circuits, backup generators and even out-of-phase power sources are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front panel current meter offers selectable 4 segment voltage, amperage and kilowatt loading information.- 208V 30A Automatic Transfer Switch (ATS) / Metered PDU (Agency de-rated to 24A continuous)- Provides a redundant power option for critical networking equipment with a single input power cord- Digital display with selection button reports voltage, amperage and kilowatt loading information in four output segments (Segment 1: 8 C13 & 1 C19 outlets / Segment 2: 8 C13 & 1 C19 outlets / Segment 3: L6-30R outlet / Segment 4: total output of all outlets combined)- 19 built-in outlets (16 C13, 2 C19, 1 L6-30R)- Set of two 10 ft. / 3m NEMA L6-30P input cables support connection to separate PRIMARY and SECONDARY power sources- ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output as sourced from the secondary input cable until power on the primary input is restored and stable- ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a 2 UPS environment, the primary input must be connected to an online double conversion UPS similar to Tripp Lite SmartOnline series)- Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported- On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source- Super-fast switchover between primary and secondary power sources occurs in 1-5 milliseconds- Front panel LEDs confirm power availability on both input lines- TAA Compliant Version Available - Order Tripp Lite PDUMH30HVATAA
Tripp Lite PDU121506. PDU types: Basic, Rack capacity: 0U/1U, Type: Single-phase. AC outlets quantity: 13 AC outlet(s), AC outlet types: NEMA 5–15R, Power plug: NEMA 5–15P. Cable length: 72"" (1.83 m). Nominal input voltage: 100 - 127 V, Maximum current: 15 A, AC input frequency: 50 - 60 Hz. Width: 20"" (508 mm), Depth: 4.5"" (114.3 mm), Height: 1.75"" (44.4 mm)
Switched PDU Provides Advanced Network Control and Remote Power MonitoringThis 0U PDU is an ideal low-cost option for small-scale network configurations where only one or two outlets are needed. It features two NEMA 5-15R individually switched outlets, which can be remotely controlled to turn on, turn off, recycle or lock out power to unresponsive devices. Front-panel LEDs indicate each outlet’s on/off status.Built-In LX Platform Network Interface Offers 24/7 AccessThe built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities, including temperature and humidity conditions. Automated alerts help prevent accidental overloads, power loss and downtime. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2c, SNMPv3, telnet, SSH, FTP, DHCP and NTP. DHCP/Manual configuration lets you assign network settings to the card automatically, reducing the need for manual configuration.Reduce Service Calls with Auto Probe Autonomous Device ManagementThe Auto Probe feature (Firmware 15.5.2 and greater) checks the connectivity status of any networked device and automatically takes one or more user-configured actions if the device fails to respond; actions include outlet reboot, set SNMP traps, SNMP OID sets, and even script execution when used in conjunction with the Tripp Lite PowerAlert Network Shutdown Agent (PANSA).Easy Connection to an AC Power SourceA six-foot power cord with NEMA 5-15P plug connects the PDU15NETLX 0U PDU to a compatible AC power source, generator or protected UPS.Flexible Installation OptionsThe switched PDU mounts vertically in 0U of rack space, on a wall or under a counter using the included mounting brackets and user-supplied hardware. Its half-width rack-mount form factor allows you to place it on a shelf or desktop.TAA-Compliant for GSA Schedule PurchasesThe PDU15NETLX is compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases.2-Year Warranty and Environmentally Responsible DesignThe rugged metal PDU15NETLX comes with a 2-year warranty. It’s manufactured in compliance with strict RoHS specifications, reflecting Tripp Lite’s commitment to environmental responsibility.Typical Applications- Provide 100-127V power for up to 2 devices in a small-scale network configuration- Remotely monitor, control and reboot power to connected equipment in data centers and computer rooms- Manage kiosks and other unattended applicationsPackage Includes- PDU15NETLX 1.4kW 100/127V Single-Phase Switched Mini PDU- (2) Mounting brackets w/screws- Owner’s manual
Tripp Lite 3-Phase PDU Monitored 14.5kW 200/208/240V 42 C13; 6 C19 60A 0URM - IEC 60309 60A BLUE (3P+E) - 6 x IEC 60320 C19, 42 x IEC 60320 C13 - 230 V AC - Network (RJ-45) - 0U - Vertical - MountRack-mountable - TAA Compliant - TAA Compliance
Tripp Lite PDU 3-Phase Monitored 18.7kW 208/240V 36 C13 60A Blue 0U TAA - Monitored - IEC 60309 60A BLUE (3P+E) - 36 x IEC 60309 C13 - 230 V AC - Network (RJ-45) - 0U - Vertical - Rack Mount - Rack-mountable - TAA Compliant - TAA Compliance
Tripp Lite 3-Phase PDU Monitored 10kW 200/208/240V 42 C13; 6 C19; L15-30P - Monitored - NEMA L15-30P - 6 x IEC 60320 C19, 42 x IEC 60320 C13 - 230 V AC - Network (RJ-45) - 0U - Vertical - MountRack-mountable - TAA Compliant - TAA Compliance
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA