3-Phase 360-415V input / 208V-240V output PDU Distributes Network-Grade Power to Multiple LoadsThis basic rack PDU (rPDU) is an ideal no-frills unit for networking, telecom, security, audio/video and sound reinforcement applications. Recommended for small to mid-sized data centers, computer rooms and network closets, the PDU3XV6G20 features 36 C13 and six C19 (208-240V) outlets in three single-phase output load banks for connecting equipment. A six-foot (1.8-meter) cord with IEC 309 16/20A Red 360-415V (3P+N+E) 3-phase input plug connects to your facility’s AC power source, generator or protected UPS system to distribute power to connected loads.Easy to Install Vertically in an EIA-Standard 19 in. RackThe 70-inch 0U PDU’s all-metal housing mounts vertically using the pre-installed toolless mounting buttons or the included brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. Cable retention brackets keep power cords organized and your rack free of clutter. The PDU’s switchless design helps prevent an accidental shutdown, which could lead to costly downtime.
Bypass PDU Recommended for Maintaining Continuous Power During UPS MaintenanceKeeping mission-critical data center equipment operating at its optimal level often means scheduledmaintenance. But what if you are unable to afford the costly downtime involved in powering down forregular upkeep? This 100-125V 12A single-phase hot-swap PDU works in conjunction with your UPSsystem to keep everything running 24/7/365. It allows you to manually transfer connected equipment toutility power via the PDU’s bypass switch, permitting maintenance or equipment replacement with nointerruption of performance.Features Dual Inputs and a Manual Transfer Switch for Uninterrupted OperationThe PDUB151U includes separate UPS and utility input cables with NEMA 5-15P plugs. The manualtransfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace theUPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipmentconnected to the six NEMA 5-15R outlets will continue to operate without interruption.Optional ECO Switching Feature Enables Cost-Cutting Power SavingsBy enabling the ECO power saving feature, you can power off a single bank of five controlled 5-15Routlets all at once when the device connected to the master 5-15R outlet is powered off or goes into a lowpower consumption mode. Mounts into 1U of Rack Space or WallUse the included mounting hardware to install the PDUB151U’s all-metal housing into 1U of space in anEIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall.
Bypass PDU Recommended for Maintaining Continuous Power During UPS MaintenanceKeeping mission-critical data center equipment operating at its optimal level often means scheduled maintenance. But what if you are unable to afford the costly downtime involved in powering down for regular upkeep? This 200–250V 10A single-phase hot-swap rack PDU (rPDU) works in conjunction with your UPS system to keep everything running 24/7/365. It allows you to manually transfer connected equipment to utility power via the PDU’s bypass switch, permitting maintenance or equipment replacement with no interruption of performance.Features Dual Inputs and a Manual Transfer Switch for Uninterrupted OperationThe PDUBHV101U features two C14 inlets that connect to separate UPS and utility input power sources with user-supplied power cables or the included C13-to-C14 cables. The manual transfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace the UPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipment connected to the six C13 outlets will continue to operate without interruption.Optional ECO Switching Feature Enables Cost-Cutting Power SavingsBy enabling the ECO power saving feature, you can power off a single bank of five controlled C13 outlets all at once when the device connected to the master C13 outlet is powered off or goes into a low-power consumption mode. Mounts into 1U of Rack Space or on a WallUse the included mounting hardware to install the PDUBHV101U’s all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall.
Single-Phase 20A ATS rack PDU (rPDU) Distributes and Monitors Network-Grade Power in Real TimeThis monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via its built-in network interface. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMNH20HVAT1 features eight C13 and two C19 200–240V outlets for connecting equipment. Dual 12-foot (3.7-meter) power cords with C20 inputs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources. Switches from Primary to Secondary Power Source in MillisecondsAutomatic transfer switching (ATS) allows the PDU to switch to the secondary source within 2–7 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source.Pre-Installed WEBCARDLX Network Interface Offers 24/7 Remote Access for Monitoring and ControlThe HTML5-based WEBCARDLX network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. The latest version of PowerAlert Device Manager (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations.Digital Load Meter Helps Prevent Potentially Expensive OverloadsA digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low.Mounts into 1U of Rack SpaceUse the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack.TAA-Compliant for GSA Schedule PurchasesThe PDUMNH20HVAT1 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
Single-Phase 120V PDU Distributes and Monitors Network-Grade Power to Multiple LoadsThis local metered PDU is an ideal unit for telecom, security, audio/video and a wide variety of general portable and stationary rack-mount applications. Recommended for network-grade IT environments, the PDUMH30-ISO provides real-time monitoring of load levels via its built-in digital current metering. A 15-foot (4.6-meter) cord with L5-30P input plug connects to your facility’s AC power source, generator or protected UPS system to distribute power to connected loads.Digital Load Meter Helps Prevent Potentially Expensive OverloadsThe PDUMH30-ISO features 12 NEMA 5-15/20R outlets in two separately breakered load banks. A digital ammeter reports the load for each bank separately, so you can balance loads across both built-in 20A breakers. Add the two load-bank current values together to determine total input current. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels can keep your TCO (total cost of ownership) low.3840 Joules per Load Bank Fight Back Against Unexpected Power SurgesProtecting your valuable electronics is ISOBAR® network-grade AC surge and noise suppression. A 3840-joule surge protection rating defends your sensitive electronic components against even the strongest power surges, spikes and line noise. The PDUMH30-ISO covers full normal (H-N) and common (N-G/H-G) protection modes. A green LED confirms your connected equipment is protected.Up-to-Date Safety Features Protect Your Vital EquipmentThe switchless design helps prevent an accidental shutdown, which could lead to costly downtime. Circuit breakers protect connected components from dangerous overloads.Versatile Installation Options Give You Plenty of ChoicesThe reversible all-metal housing comes with mounting brackets for installation in 1U of space or 0U vertical mounting in an EIA-standard 19-inch rack. You can also reorient the brackets for permanent mounting under a counter or on a wall with user-supplied hardware.
Tripp Lite series 12.6kW 200-240V 3-Phase IsoBreaker Managed PDU - Gigabit, 36 Outlets, IEC-309 60A Blue (3P+E) Input, LCD, 10 ft. (3 m) Cord, 0U, 70 in. (1.8 m) Height, TAA - Managed, Switched - IEC 60309 60A BLUE (3P+E) - 30 x IEC 60320 C13, 6 x IEC 60320 C19 - 230 V AC - 0U - Vertical - Rack-mountable - Vertical - TAA Compliant - TAA Compliance
Tripp Lite series 12.6kW 200-240V 3-Phase IsoBreaker Managed PDU - Gigabit, 36 Outlets, CS8365C Input, LCD, 10 ft. (3 m) Cord, 0U, 70 in. (1.8 m) Height, TAA - Managed, Switched - Hubbel CS8365C 50A - 30 x IEC 60320 C13, 6 x IEC 60320 C19 - 230 V AC - 0U - Vertical - Rack-mountable - Vertical - TAA Compliant - TAA Compliance
Tripp Lite series 8.6kW 200-240V 3-Phase IsoBreaker Managed PDU - Gigabit, 36 Outlets, L15-30P Input, LCD, 10 ft. (3 m) Cord, 0U, 70 in. (1.8 m) Height, TAA - Managed, Switched - NEMA L15-30P - 30 x IEC 60320 C13, 6 x IEC 60320 C19 - 230 V AC - 0U - Vertical - Rack-mountable - Vertical - TAA Compliant - TAA Compliance
Tripp Lite series 8.6kW 200-240V 3-Phase IsoBreaker Managed PDU - Gigabit, 36 Outlets, L21-30P Input, LCD, 10 ft. (3 m) Cord, 0U, 70 in. (1.8 m) Height, TAA - Managed, Switched - NEMA L21-30P - 30 x IEC 60320 C13, 6 x IEC 60320 C19 - 230 V AC - 0U - Vertical - Rack-mountable - Vertical - TAA Compliant - TAA Compliance
Tripp Lite PDU Switched 2.9kW 120V 24 5-15/20R LX Platform Interface 0U TAA - Switched - NEMA L5-30P - 24 x NEMA 5-15/20R - 120 V AC - Network (RJ-45) - 0U - Vertical - Rack Mount - TAA Compliant - TAA Compliance
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA