Flat 5% Discount for Gov, Edu & Corporate clients.
Eaton RCP200-BLK 2-Outlets PDU - NEMA 5-15P - 2 x NEMA 5-15R - 120 V AC - 2U - Rack-mountable - RoHS Compliance
The RELAYIOMINI allows users to communicate UPS status and events via three contact closure outputs. Installs in the back panel of compatible power modules on select SmartOnline® UPS systems only. Requires removal of USB module to install.NOTE: Compatible with SmartOnline® UPS systems specifying the use of this accessory from 5 to 20kVA originally shipping with preinstalled back-panel USB module and dedicated RS-232 DB9 port. Compatible models: SU5000RT4UHV, SU5000RT4UTF, SU6000RT4U, SU6000RT4UHVG, SU6000RT4UHVHW, SU6000RT4UTF, SU6000RT4UTFHW, SU8000RT3U, SU8000RT3UG, SU8000RT3UHW, SU8000RT3U1TF, SU8000RT3UN50, SU8000RT3UN50TF, SU10000RT3U, SU10000RT3UG, SU10KRT3U, SU10KRT3UHV,SU10000RT3U2TF, SU12KRT4UHW, SU16KRT, SU16KRT-1TF, SU16KRTG, SU16KRTHW, SU20KRT, SU20KRT-1TF, SU20KRTG, SU20KRTHW.
Get Complete Step-Down/Step-Up and Isolation ProtectionTripp Lite’s S3MT-100K600V 100kVA/kW transformer offers line isolation and protection to the connected 3-phase UPS system and its load. It isolates the UPS and connected components from line surges and spikes caused by utility power disruptions that can damage equipment or corrupt data. The step-down input isolation transformer is ideal for 4-wire (3Ph+N+PE) IT loads in government, manufacturing, healthcare and corporate settings with a 600V electrical feed and 208/120V equipment.Performs with High Efficiency up to 97.7%Not only is the S3MT-100K600V very efficient, with up to 97.7 percent efficiency, but it is also very quiet with a noise profile less than 65 dBA. A built-in circuit breaker on the output side helps prevent dangerous power overloads. Three ball-bearing cooling fans help prevent overheating. An overheat-sensing relay and switch combine with a red LED indicator to provide over-temperature warning and overheating protection.Small Footprint for Quick Installation in a Compact SpaceThe compact footprint enables installation of the S3MT-100K600V with minimal space. The rugged stainless steel housing ships ready for immediate tower installation with a compatible 80–100kVA/kW Tripp Lite S3M-Series 208V 3-phase UPS system.
Get Complete Step-Down and Isolation Protection and Prevent Power DisruptionTripp Lite’s S3MT-20K480V 20kVA/kW transformer offers line isolation and protection to the connected 3-phase UPS system and its load. It isolates the UPS and connected components from line surges and spikes caused by utility power disruptions that can damage equipment or corrupt data. The step-down input isolation transformer is ideal for 4-wire (3Ph+N+PE) IT loads in government, manufacturing, healthcare and corporate settings with a 480V electrical feed and 208/120V equipment.Performs with High Efficiency up to 96.5%Not only is the S3MT-20K480V very efficient, with up to 96.5 percent efficiency, but it is also very quiet with a noise profile less than 65 dBA. A built-in circuit breaker on the output side helps prevent dangerous power overloads. Two ball-bearing cooling fans help prevent overheating. An overheat-sensing relay and switch combine with a red LED indicator to provide over-temperature warning and overheating protection.Small Footprint for Quick Installation in a Compact SpaceThe compact footprint enables installation of the S3MT-20K480V with minimal space. The rugged stainless steel housing ships ready for immediate installation with a compatible 10–20kVA/kW Tripp Lite S3M-Series 3-phase UPS system.
Get Complete Step-Down/Step-Up and Isolation ProtectionTripp Lite’s S3MT-60K600V 60kVA/kW transformer offers line isolation and protection to the connected 3-phase UPS system and its load. It isolates the UPS and connected components from line surges and spikes caused by utility power disruptions that can damage equipment or corrupt data. The step-down input isolation transformer is ideal for 4-wire (3Ph+N+PE) IT loads in government, manufacturing, healthcare and corporate settings with a 600V electrical feed and 208/120V equipment.Performs with High Efficiency up to 97.5%Not only is the S3MT-60K600V very efficient, with up to 97.5 percent efficiency, but it is also very quiet with a noise profile less than 65 dBA. A built-in circuit breaker on the output side helps prevent dangerous power overloads. Four ball-bearing cooling fans help prevent overheating. An overheat-sensing relay and switch combine with a red LED indicator to provide over-temperature warning and overheating protection.Small Footprint for Quick Installation in a Compact SpaceThe compact footprint enables installation of the S3MT-60K600V with minimal space. The rugged stainless steel housing ships ready for immediate tower installation with a compatible 50–60kVA/kW Tripp Lite S3M-Series 208V 3-phase UPS system.
the T1/e1 Copper To Fiber Network Interface Device (nid) Provides A Solution For Those Users That Need To Extend T1/e1 Connections Over Fiber.the T1/e1 Supports Small Form Pluggable (sfp) Transceivers To Support A Variety Of Fiber Types, Distances And Wavelengths To Provide Maximum Flexibility Across A Variety Of Network Topologies. The Use Of Coarse Wave Division Multiplexing (cwdm) Sfps Can Be Utilized To Further Increase The Bandwidth Capacity Of The Fiber Infrastructure.the T1/e1nid Must Be Used In Pairs. A Typical Installation Will Include A Chassis Card Installed In The Ion Platform Locally And A Stand-alone Device Installed At The Remote Location.
the Ion S6110 Is A Managed Stand-alone T1/e1/j1 Media Converter Mux And Provides A Solution For Those Users That Need To Extend Multiple T1/e1/j1 Connections Over Fiber. The S6110 Includes (4) Rj-48 Ports And (1) Fiber Port. The Device Is Available In Versions That Support Fixed Fiber Connectors As Well As Sfp Fiber Modules Offering Support For A Variety Of Fiber Types, Distances, And Wavelengths To Provide Maximum Flexibility Across A Variety Of Network Topologies. Cwdm Sfps Can Also Be Utilized To Further Increase The Bandwidth Capacity Of The Fiber Infrastructure. The S6110 Converter Must Be Used In Pairs. Management Of The Stand-alone Converter Is Supported, In-band, Over The Fiber, When The Remote S6110 Is Linked To A C6110 Card Installed In A Managed Ion Chassis.
the Ion S6120 Is A Managed Stand-alone T1/e1/j1 Media Converter Mux And Provides A Solution For Those Users That Need To Extend Multiple T1/e1/j1 Connections, Along With A 10/100 Ethernet Connection, All Over Fiber. The S6120 Includes (4) Rj-48 Ports, (1) 10/100 Ethernet Port, And (1) Fiber Port. The Device Is Available In Versions That Support Fixed Fiber Connectors As Well As Sfp Fiber Modules Offering Support For A Variety Of Fiber Types, Distances, And Wavelengths To Provide Maximum Flexibility Across A Variety Of Network Topologies. Cwdm Sfps Can Also Be Utilized To Further Increase The Bandwidth Capacity Of The Fiber Infrastructure. The S6120 Converter Must Be Used In Pairs. Management Of The Stand-alone Converter Is Supported, In-band, Over The Fiber, When The Remote S6120 Is Linked To A C6120 Card Installed In A Managed Ion Chassis.
the Ds3 - T3/e3 Copper To Fiber Network Interface Device (nid) Provides A Solution For Those Users That Need To Extend Ds3 Connections Over Fiber.the Ds3 - T3/e3s Supports Small Form Pluggable (sfp) Transceivers To Support A Variety Of Fiber Types, Distances And Wavelengths To Provide Maximum Flexibility Across A Variety Of Network Topologies. The Use Of Coarse Wave Division Multiplexing (cwdm) Sfps Can Be Utilized To Further Increase The Bandwidth Capacity Of The Fiber Infrastructure.the Ds3 - T3/e3 Nid Must Be Used In Pairs. A Typical Installation Will Include A Chassis Card Installed In The Ion Platform Locally And A Stand-alone Device Installed At The Remote Location.
the Redundant Link Protector Is A 10/100 Ethernet Fault-tolerant Transceiver. It Significantly Reduces Network Downtime, Adding A New Level Of Redundancy To 10/100 Ethernet Connections. It Also Provides A Redundant Path For Critical 10/100 Devices. In A 10/100 Ethernet Network, A Critical Device Such As A File Server May Be Connected To The Rest Of The Network Through A Hub Or A Switch. A Common Problem In This Configuration Is That The Server Is Often Connected To The Network Through A Single Cable. If The Cable Fails, Then The Server Is Disconnected From The Rest Of The Network. Similarly, If A Port Of A Hub Or Switch To Which The Server Is Connected Fails, The Server Is Disconnected From The Network.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA