Flat 5% Discount for Gov, Edu & Corporate clients.
Tripp Lite PDU Switched ATS 208V 30A 16 C13; 2 C19; 1 L6-30R Horizontal 2U TAA - 1 x NEMA L6-30R, 2 x IEC 60320 C19, 16 x IEC 60320 C13 - 208 V AC - 2U - Horizontal Rackmount" - RoHS, TAA Compliance
32A single phase 230V Local Metered Power Distribution Unit / rack PDU (rPDU)Set of two lighted current meters separately report power consumption in amps for each output load bankAttached IEC-309 32A (2P+E) input plug with 12-ft. (3.66 m) line cord2U horizontal rackmount format installs in two rack spaces18 total 230V outlets (2 C19, 16 C13)Outlets are arranged in two separately breakered and local metered 16A load banks (each with 8 C13 and 1 C19 outlet)Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formatsMounting ears are reversible for front or rear facing rackmount installationFront-panel grounding lugIncluded cord retention brackets
The PDUMH32HVAT 7.7kW Single-Phase 200-240V Local Metered Automatic Transfer Switch / ATS PDU provides power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 2U of space in EIA-standard 19-inch racks and features 18 outlets (16 C13 and two C19) in two load banks, each bank protected by a 20A circuit breaker.Dual three-meter input cords with IEC 309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase 200-240V power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.Multifunction digital display with LED indicators reports output current, voltage and kW loading information.
The PDUMH32HVATNET 7.7kW Single-Phase 200-240V Switched Automatic Transfer Switch / ATS PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 2U of space in EIA-standard racks and features 18 switched outlets (16 C13 and two C19) in two load banks, each bank protected by a 20A circuit breaker.Dual 3-meter input cords with IEC309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase 230V power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.Built-in LX Platform network management interface. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separate) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
This Switched PDU offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption. Built-in LX Platform network management interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. Individually switched outlets can be controlled in real time to remotely reboot unresponsive network hardware or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps is displayed locally via front panel current meter or remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip.
Tripp Lite single phase Monitored PDU / Power Distribution Unit offers real-time remote monitoring of voltage, frequency and load levels via built-in network connection. PowerAlert interface supports custom notification of user-specified remote conditions via email, secure web, SNMP, Telnet or SSH interface. PDU lighted digital display enables visual monitoring of PDU output current to prevent circuit overloads as additional equipment is added. Offers reliable rackmount multi-outlet power distribution from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.- 15A single phase 120V Monitored Power Distribution Unit / PDU (agency derated to 12A continuous)- Attached NEMA 5-15P input plug with 12ft / 3.6m line cord- 1U horizontal rackmount installation format supports installation in 2 or 4 post equipment racks- 8 NEMA 5-15R outlets- Lighted display reports output power consumption in amps- Built-in SNMP/ethernet interface reports voltage, frequency and PDU loading via network or secure web browser interface with options for user specified alarm and notification thresholds- Supports in-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors- DHCP/Manual configuration support- 10/100 Mbps auto-sensing allows optimal communication with 10/100 Base-T networks- Real-time clock backup maintains the time of day and date even if the PDU is unpowered- Tiered access privileges allow an administrator and a guest to login via web browser for monitoring- Alert notifications via email or SNMP traps offer immediate event notification- Firmware upgrade ability supports future product enhancements.- Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols- Fully compatible with FREE PowerAlert Network Management System / NMS Software- Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formats- Mounting ears are reversible for front or rear facing rackmount installation- Included cord retention brackets keep vital network equipment plugged in and continuously powered- TAA Compliant Version Available - Order Tripp Lite PDUMNH15TAA
The PDUMNH16HVAT 3.8kW Single-Phase 200-240V Monitored Automatic Transfer Switch / ATS PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and has an IEC309 16A Blue outlet for connecting a single device or a 0U 230V vertical PDU with IEC309 16A Blue plug.Dual 10-ft. (3.05 m) input cords with IEC309 16A Blue plugs connect to separate primary and secondary single-phase power sources, including out-of-phase sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds if the primary source fails or becomes unstable to ensure connected equipment remains powered.Built-in LX Platform network management interface. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separate) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. Digital display with LEDs indicates power availability, voltage, input status for both power sources, output load and power factor, as well as temperature and humidity conditions with optional ENVIROSENSE2 module (sold separate).
High-capacity 3.3/3.8kW PDU with ATS provides remote power monitoring and enables redundant power for non-redundant hardware. Digital display and Ethernet interface monitor load levels to prevent overloads that cause downtime.- Two single-phase L6-20P inputs with 10 ft. cords- L6-20R outlet for connecting single device or 0U vertical PDU- Automatic transfer switching within 1–5 ms- Ethernet network interface for remote access- Digital display for real-time status monitoringThe PDUMNH20HVAT 3.3/3.8kW Single-Phase 208/240V ATS/Monitored PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and features one L6-20R outlet—perfect for connecting a single device or a 0U 208/240V PDU with an L6-20P plug. Dual 10-foot input cords with L6-20P plugs connect to separate primary and secondary single-phase power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption. Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP. Provides real-time load/current data with billing-grade accuracy (+/- 1 percent). Tiered access privileges allow both an administrator and a guest to log in. Automated alerts help prevent accidental overloads, power loss and downtime. Digital display indicates power availability, voltage, source A/B input status, output load and power factor, as well as temperature and humidity conditions with the optional ENVIROSENSE module (sold separately).Primary and Secondary Inputs for Power Redundancy- Provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations- Dual 10 ft. input cords with L6-20P plugs connect to separate primary and secondary single-phase power sources- Fault-tolerant, hot-swappable UPS protection when used with single UPS; fully redundant UPS protection when each cord is connected to separate UPS systemsBuilt-In L6-20R OutletConnects a single device or indirectly powers equipment through a 0U 208/240V PDU with L6-20P input (sold separately)Automatic Transfer Switching (ATS)- Dynamic solid-state (TRIAC) automatic transfer switching- Switches to secondary power source if primary source fails or becomes unstable- 1–5 ms transfer time ensures uninterrupted operation of connected equipment- Built-in processor prevents switching if secondary source is unavailable or of lower quality than primary sourceMultifunction Digital Display- Reports source A and source B input power status and other information, including power availability, line voltage, frequency, amps, kilowatts and power factorAdvanced Network Monitoring- Built-in Ethernet network interface allows full remote access for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP- Real-time load/current data with billing-grade accuracy (+/- 1 percent)- Automated alerts help prevent overloads, power loss and downtime- Optional ENVIROSENSE module (sold separately) monitors temperature and humidityBroad Communications Compatibility- Supports HTTP, HTTPS, PowerAlert®, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP and NTP- 10/100 Mbps auto-sensing allows optimal communication with 10/100 Base-T networksMounts Horizontally in 1U of Rack Space- Compatible with EIA-standard 19 in. 4-post racks and rack enclosures- Optional PDU4PKIT rail kit (sold separately) adds rear mounting support
Tripp Lite by Eaton 2.9kW 120V Single-Phase ATS/Monitored PDU - 24 5-15/20R & 1 L5-30R Outlets, Dual L5-30P Inputs, 10 ft. Cords, 2U, TAA - Monitored - NEMA L5-30P - 24 x NEMA 5-15/20R, 1 x NEMA L5-30R - 120 V AC - Network (RJ-45) - 2U - Horizontal - Wall-mountable, Rack-mountable - TAA Compliant - TAA Compliance
Tripp Lite PDUMNH30HVAT2 19-Outlets PDU - Monitored - NEMA L6-30P - 16 x IEC 60320 C13, 2 x IEC 60320 C19, 1 x NEMA L6-30R - 230 V AC - Network (RJ-45) - 2U - Horizontal - Wall-mountable, Rack-mountable - TAA Compliant - TAA Compliance
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA