Vertiv Geist Monitored Rack PDU - (36) IEC C13| (6) IEC C19| L6-30P| RPDU - Monitored - 36 x IEC 60320 C13, 6 x IEC 60320 C19 - 230 V - Vertical - Rack Mount - Rack-mountable
Liebert Basic PDU - Horizontal, 120/208V, (8) NEMA 5-20R, (2) NEMA L6-30R - Basic - 8 x NEMA 5-20R, 2 x NEMA L6-30R - 120 V AC, 230 V AC - 2U - Horizontal - Rack-mountable - Rack - TAA Compliant
The Vertiv Geist Switched Unit Level Monitored Rack PDU VP5N3000 is a 30A, 208V 0U vertical rack power distribution unit (PDU) with input power monitoring, and outlet level switching. The VP5G3000 has 24 Combination C13/C19 outlets and a L6-30P plug with a 3m cord providing 4.9kW in power capacity. This Switched rPDU allows you to turn off receptacles to avoid accidental overloads and power cycle equipment remotely to reboot unresponsive critical IT equipment. The hot-swappable Interchangeable Monitoring Device (IMD) displays current on the local LED display. The IMD includes ports for serial communication and environmental monitoring, and dual ethernet ports. Simplify management of multiple PDUs with fault-tolerant daisy chaining or IP aggregation capabilities. This Vertiv Geist Switched PDU is UL listed, meeting an important requirement for data centers, and each unit undergoes individual testing for functionality to ensure your network is powered by a reliable power distribution unit.
FOR 5-10KVA MV GXT5
Vertiv Liebert POD PD5 - (2) NEMA L6-30R| (4) NEMA 5-15/20R| UPS Maintenance Bypass for GXT5 (PD5-003)
Vertiv Liebert MicroPOD - (8) NEMA 5-20R| 16A| UPS Maintenance Bypass/Switch - (3) NEMA 5-20P| Max Current 16A| AC 120V| for GXT and PSI UPS| 3kVA and belowThe Vertiv Liebert MicroPod External Maintenance Bypass POD (MP2-120C) is an external power output distribution (POD) unit and maintenance bypass switch for your uninterruptible power supply (UPS) unit. With the MicroPod, you can avoid initiating unnecessary downtimes during UPS maintenance or replacements. It allows the manual transfer of power from the UPS to the utility source without power interruption to the connected load, ensuring continuous uptime for your critical operations. The MicroPod MP2-120C is designed for the Vertiv Liebert GXT and Vertiv Liebert PSI UPS 3kVA models and below, but is compatible with other UPS brands as well. It comes with brackets for easy rack mounting and is equipped with three NEMA 5-20P input connectors. The MicroPOD has eight NEMA 5-20R output connectors and is available at 120V and supports a max current of 16A. More from the Manufacturer
VERT 20A 120V 24X5-20R
Upgradeable Switched Unit Level Monitored EC rPDUs provide reliable power distribution to critical IT equipment while delivering individual outlet level control and a comprehensive view of input power usage via remote network access. Includes environmental monitoring capabilities to obtain real-time environmental metrics. Upgrade the hot-swappable monitoring device on select units to leverage new technologies and accommodate changing business needs.
This specification defines the electrical and mechanical characteristics and requirements for a continuous-duty, single-phase, maintenance bypass / power output distribution system. This system, hereafter referred to as the POD, provides high-quality maintenance by pass capability for all micro UPS products up to and including 3kVA.The POD is designed in accordance with the applicable sections of the current revision of the following standards. Where a conflict arises between these standards and statements made herein, the statements in this specification shall govern. The POD is stand alone UL listed. The POD units can be used with any manufactures UPS that meets the UL standards listed below.
Vertiv Liebert MicroPOD - (8) NEMA 5-20R| 24A| UPS Maintenance Bypass/Switch - (3) NEMA L5-30P| Max Current 24A| AC 120V| for GXT and PSI UPS| 3kVA and below - TAA Compliance