Wallmount Rack Enclosure Cooling Roof Fan Kit 120V 5-15P
Bracket Enhances Functionality of Enclosures and Open Frame RacksThe SRPDU4PHDBRKT allows the addition of up to three vertical PDUs or cable managers to a rack enclosure or open frame rack, helping you avoid the need to invest in a larger rack configuration. Upper and lower brackets attach to the frame of a standard or heavy-duty rack enclosure using the included screws and cage nuts. Included adapter plates allow connection to mounting rails in 2-post or 4-post open frame racks. Supports Toolless Mounting of Up to 3 Vertical PDUs or Cable ManagersUp to three vertical PDUs or cable management accessories can be mounted to the SRPDU4PHDBRKT brackets. Keyhole slots support toolless button mounting. The brackets also have equipment mounting holes for attaching PDUs and cable managers with fasteners.
1U Vented Cantilevered Rack Shelf Secures Non-Rack Equipment in Your Data CenterThis SmartRack® cantilevered shelf supports monitors, power strips, PDUs, wireless access points and other network and IT equipment not typically stored in a rack. Made from heavy-duty cold-rolled steel with a durable black powder-coated finish, the SRWSHELF4P1U has a maximum load capacity of 50 lbs (22.2 kgs). Its adjustable rails mount easily into 1U of space in EIA-standard 19-inch enclosures and open frame racks using included hardware.Custom Setup Maximizes Rack Space and Saves Desk or Floor Space in a Busy OfficeThe steel shelf is 14.2 inches deep. The surface is perforated with square mounting holes that accept cage nuts, giving you multiple options for installing equipment for convenient access. The vented surface also augments proper airflow to keep your equipment cool and functioning at its peak. Built-in flexible cable rings help you manage and secure cabling and cut down on intrusive cord clutter.
Increase ventilation inside your rack enclosures and server cabinets. Keep your valuable rack equipment cool and functioning efficiently without costly failures that lead to downtime, damage and data loss.- 3 durable 4 in. 120V high-performance fans- 6 ft. AC power cord with 5-15P plug- Fans circulate air at 210 cubic feet per minute (CFM)- Heavy-duty cold-rolled steel construction- Fully assembled and ready to mountThe SRFAN1U SmartRack 1U Fan Tray is an ideal accessory for increasing ventilation within your rack enclosures and server cabinets. Better airflow keeps your valuable rack components cool, helps boost system performance, and avoids costly equipment failures that lead to downtime, damage and data loss.The SRFAN1U requires only one rack space and installs easily in an enclosure or server cabinet. It includes three powerful four-inch 120V fans that should be mounted low in the rack in order to push cool air toward the top. The high-performance fans circulate air at 210 cubic feet per minute (CFM). The 1U tray is constructed from heavy-duty cold-rolled steel that is built to last. The six-foot AC power cord plugs into any NEMA 5-15R outlet.Better Rack Ventilation Means Better Operating Equipment- Ideal for keeping rack components cool, boosting system performance, and avoiding costly equipment failures- 3 powerful 4 in. 120V fans push air toward top of the rack- Circulates air at 210 cubic feet per minute (CFM)Heavy-Duty Construction- Built using heavy-duty cold-rolled steel designed to last a long time- 6 ft. AC power cord plugs into any NEMA 5-15R outlet- Compatible with all standard 19 in. rack enclosures and server cabinets- Fully assembled and ready to mount
Enables the secure placement of one SmartPro and SmartOnline 2U UPS or battery pack in 2-post rack-mount or wallmount applications
The 4POSTRAILKIT adjustable rack-mount shelf system supports heavy UPS systems in 4-post rack-mount applications. Includes one pair of expandable ""L bracket"" mounting rails to offer front-to-rear support of rack-mount UPS systems. Pair of expandable ""L brackets"" adjust to any setting between 20.5 and 36 inches. Includes mounting hardware compatible with square-hole racks. Set of temporary placement pegs enables simple single-person installation by allowing the rails to be held in place while attachment hardware is installed. Also compatible with other heavy pieces of networking or power protection equipment with 17.5-inch-wide rectangular chassis. Supports up to 250 pounds (113.4 kilograms).
The SRCOOL7KDUCT SmartRack® Exhaust Duct Kit is a venting system accessory for the SRCOOL7KRM Rack-Mounted Air Conditioning Unit. It directs and disperses heat from the SRCOOL7KRM through an upper vent into your facility’s dropped ceiling plenum, return air duct or other standard ventilation system. By keeping your rack equipment cool and performing at its peak, the SRCOOL7KDUCT helps the SRCOOL7KRM reduce your cooling and energy costs.Ideal for small-space applications where heat is unlikely to disperse on its own, such as an IT closet, the SRCOOL7KDUCT installs using the included hardware. Two magnetic tube adapters attach to the rack’s vented rear door to make the kit compatible with EIA-standard rack enclosures and open frame racks that accommodate the SRCOOL7KRM.
The SR42UBMDEXPND offers 36 inches (927 millimeters) of depth opposed to the standard 42 inches.The SR42UBMDEXPND is a 42U SmartRack® enclosure with no doors and no side panels. The 'EXP' version is an expansion model used when several cabinets are bayed together. Its integrated baying tabs make it easy to combine multiple enclosures in rows for data center applications. This enclosure is also compatible with hot-aisle/cold-aisle configurations.The SR42UBMDEXPND houses 3,000 pounds (1360.8 kilograms) of standard 19-inch rack equipment in 42U. Its front and rear pairs of vertical rails have square mounting holes that are adjustable in quarter-inch increments from four to 28.75 inches. Adjustment is quick and an easy-view depth index ensures consistent rail placement without requiring time-consuming measurements. Each rack space within the enclosure is numbered for ready reference.Two of the adjustable vertical mounting rails support toolless button-mount 0U installation of up to four compatible PDUs and cable managers. This feature makes it easier to route cabling to rack equipment and reduces cord clutter.All components of the SR42UBMDEXPND are grounded to the enclosure frame. Front and rear threaded grounding points are provided for connection to the facility earth ground.To simplify deployment, the SR42UBMDEXPND comes with preinstalled casters that enable it to be easily maneuvered into the desired location, where it can be secured by adjusting the preinstalled levelers. Note: The casters are intended for minor position adjustments and are not designed for moving the enclosure over long distances.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA