APC by Schneider Electric Rack PDU, Switched, 2U, 30A, 120V, (16)5-20 - Switched - NEMA L5-30P - 16 x NEMA 5-20R - 120 V - 2U - Rack-mountable - TAA Compliance
Catastrophic Event ProtectionSurgeArrest components such as MOVs and Thermal fuse ensure instantaneous reaction to lightning strikes and wiring faults. If the surge components are damaged due to power spike or over voltage, excess power cannot reach your equipment. Unlike the APC SurgeArrest products, most surge suppressors continue to let power through even after circuits have been damaged, leaving your equipment exposed to other damaging surges.EMI and RFI noise filteringReduces line noise that can cause data loss and keyboard errors.Fail Safe ModeMost other surge suppressors continue to let power through even after their circuits have been damaged, leaving your equipment exposed to future surges. APC's SurgeArrest fail safe, which means that once the circuit of an APC SurgeArrest has been compromised the unit disconnects equipment from the power supply ensuring that no damaging surges reach your equipment.IEEE let-through ratings and regulatory agency complianceAPC surge protectors undergo stringent testing by IEEE, and are awarded ""let-through ratings"", which indicate the maximum voltage level that can possibly reach your equipment after a surge or voltage spike has passed through an electric surge protector. Lower IEEE let-through ratings indicate better protection and performance. The APC Essential SurgeArrest series offers optimal performance with a let-through rating of less than 330V to 500V for North American products, and a rating of less than 15% for products sold worldwide. All APC products comply with local agency safety requirements, including UL in North America and CE/Kema/Gost/C-tick/A-Tick/Telepermit in their respective regions.Lightning and Surge ProtectionTo prevent damage to your equipment from electric power surges and spikes.Noise FilteringAttenuates EMI/RFI line noise that can cause data errors and keyboard lockups, ensuring better performance of protected equipment.Protection Working IndicatorSurgeArrest will warn you if its circuitry has been damaged by heavy strike or power line surge and it is unable to provide 100% protection. If still under warranty, APC will then replace your damaged SurgeArrest free of charge.Right Angle PlugPlug angle allows for equipment and furniture to be placed closer to the wall than with a standard power cord. Reduces cord stress too.
APC Basic Rack 10-Outlets 4.99 kVA PDU - 10 - 4.99kVA - 1U Horizontal Rackmount - TAA Compliance
Toolless Mounting CapabilitiesUnits do not require additional tools to mount into APC NetShelter VX, which allows the users to quickly and easily mount units in the rear of the enclosure.Vertical Mounting CapabilitiesEasily mounts vertically in racks or enclosures and occupies zero U of valuable rack space, which allows more equipment in the rack. Units that mount vertically are optimized to fit in a NetShelter VX enclosures.
APC NetShelter Rack PDU Advanced, Metered, 5.0kW, 1PH, 208V, 30A, L6-30P, 40 OutletAPC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 40 outlets in a 2.2"" wide form factor. Outlets on the PDUs are color coded by breaker to simplify deployment. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.Maximum Outlet DensityAll models include 40, 42, or 48 outlets to accommodate even the highest density of devices, allow for more installation flexibility, and provide room for growth within the PDUs power capacity limits.Space SavingWith such high outlet counts and power capacity, NetShelter Advanced Rack PDUs are designed to maximize space with their single width form factor, often allowing for fewer PDUs to accommodate the same number of devices and power requirements.High Power CapacityModels now available to provide up to 34.6kW (derated to 80% capacity per National Electric Code (NEC) for North America) and up to 43.5kW for other countries to ensure support for most any density deployment and help minimize the number of PDUs needed to do so.APC Locking Power Cord CompatibleFree up space and secure power cords between rack-mount PDUs and attached IT equipment with this easy-to-use cord retention method. Optional AP8700 power cords will fit into any standard IEC receptacle or power inlet; the ""locking"" feature is enabled when used with NetShelter Rack PDU Advanced to reduce the probability of accidental power cord disconnect.Circuit Breaker MonitoringAllows total load across each circuit breaker to be monitored for potential overload and can be configured to provide notification in the event of a circuit breaker trip.Alternating PhaseNetShelter Rack PDU Advanced incorporates an alternating phase design on 3 phase models whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU. This alternating phase layout facilitates better power cord management and more intuitive load balancing versus traditional PDU solutions where outlets are grouped by phase at the top, middle, and bottom of the PDU.60ºC (140ºF) Operating TemperatureRated and approved to operate up to 60C (140F) at full load, NetShelter Rack PDU Advanced ensures reliability and availability even in today's high density deployments.Power SharingRack PDUs cascaded together via the two ethernet ports on each PDU allow Network Management Cards (NMC) to continue functioning in the event of an AC power loss to a given PDU. Network communication is uninterrupted, attached sensors still operate, and alarm traps remain available.Hydraulic Magnetic Circuit BreakersProvide increased availability by maintaining trip current over a wide temperature range.Live Swap Network Management CardThe Network Management Card (NMC) can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event.Color Coded OutletsTo simplify deployment, outlets on the PDUs are color coded by breaker on 1 phase models and color coded and/or labeled by breaker and input phase on 3 phase models.Environmental Sensor SupportTwo environmental sensor ports allow for optional sensors (sold separately) to be connected. Sensors available within the NetSelter Rack PDU Advanced portfolio include temperature, temperature/humidity, temperature (3 sensors)/humidity, rope leak detection, and a door contact switch. Also available is an expansion hub to allow connection of up to three sensors providing the ability to manage six separate sensors from one rack PDU. Sensor availability expected late 2022.Wide Offer BreadthMetered, Switched, and Metered-by-Outlet with Switching functionality are available across all power configurations ranging from 5kW up to 34.6kW to meet the need for most deployments.Network CascadingConnect and manage up to 32 PDUs from a single IP address to simplify and speed PDU deployment while reducing networking costs associated with having a dedicated network connection for each PDU.US Based ManufacturingUS based manufacturing enables better product availability and ability to offer configure-to-order (CTO) products (optional and subject to pricing and leadtimes) including different cord lengths, plug types, and PDU chassis color.Dual RatedFor data center deployments across multiple regions, select models are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.Flexible PDU MountingWith pre-installed mounting pegs, NetShelter Rack PDU Advanced can be quickly installed in the toolless mounting holes of the rear accessory channel in a NetShelter SX and many 3rd party cabinets. Mounting pegs can be repositioned to the side of the PDU to rotate the orientation of the outlets 90 degrees and face the back of the cabinet for better clearance from device chassis or mounting rails.4-in-1 Combination OutletsOffering unparalleled flexibility, 4-in-1 combination outlets which can be used as either C13 or C19 enable a single PDU outlet layout to support various rack layouts and configurations. In addition, the same 4-in-1 combination outlets also serve as high temperature C15 and C21 outlets for devices with C16 and C22 power cords. With 4-in-1 combination outlets redeployment of a PDU with new rack layout or configuration is easy and straightforward, often preventing the need to remove and discard a PDU upon IT refresh.Color LCD DisplayNetShelter Rack PDU Advanced provides a rich color LCD display for local management and control at the rack.Dual Network PortsA second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy.1% Metering AccuracyProviding the same level of accuracy as a utility company meter by adhering to IEC 62053-21 class 1, 1% metering accuracy provides peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring.Gigabit Ethernet ConnectivityProvides Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center.Network Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web and SNMP. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time.
APC by Schneider Electric Rack PDU 2G, Switched, ZeroU, 30A, 100-120V, (24) 5-20R Switched - NEMA L5-30P - 24 x NEMA 5-20R - 100 V, 120 V - 2880 W - Overload Protection - 9.84 ft Cord Length - 0U - Rack-mountable - Tower
from The World''s Most Trusted Brand In Pdus Comes A More Reliable, Intelligent, And Faster To Deploy Pdu. Designed For Data Centers And Remote Edge Computing Environments That Are Experiencing Rising Power Densities And That Demand Always "on" It Infrastructure. It Devices In These Environments Need Certainty And Apc Netshelter 9000 Series Switched Rack Pdus Provide That With Features Making Them Faster To Deploy, Enhance Their Reliability, And Make Them More Manageable Onsite Or Remotely Anywhere In The World With Ecostruxure It. More Reliable Higher Temperature Performance More Secure Power Cord Long Lasting Design More Manageable More Precise Metering Faster Ethernet Connectivity Embedded Apc Network Management Card 3 (nmc) Faster To Deploy Fast Network Setup With Network Port Sharing Cableless Install And Setup With Optional Wireless Connectivity Zero U Toolless Installation Typical Applications Cloud And Service Providers / Colocation Small, Medium, Large Data Centers Enterprise Edge Computing Finance / Insurance / Content Delivery Networks / Government Key Features:60°c High Temperature Performance Industry First Hybrid Outlets (c13/c15 & C19/c21) Provide True 60°c Operating Temperature For A Pdu. Providing The Ability To Operate In A Maximum Ambient Air Temperature Of 60°c (140°f) At Full Load Increasing Reliability And Availability Even In Today''s High Density Deployments. Other Models Allow Up To 45°c (113°f). Ecostruxure It Ready Seamless Integration Of One Or Many Pdus Including Alerts And Control With Ecostruxure It. Allows It And Data Center Professionals To Monitor And Manage All Of Their Critical It Infrastructure On-premise, In The Cloud, And At The Edge From Anywhere. More From The Manufacturer
APC AP7552 Rack PDU,Basic, Zero U, 16A, 230V, (20) C13 & (4) C19; IEC C20
APC AP7530 Basic Rack 1.92kVA PDU - 24 x NEMA 5-20R - 1.92kVA - Zero U Rack-mountable - TAA Compliance
APC APDU10452ME by Schneider Electric NetShelter 42-Outlets PDU - Metered - IEC 60309 60A (3P+PE) - 21 x IEC 60320 C13/C15, 21 x IEC 60320 C13/C15/C19/C21 - 230 V AC - 0U - Rack - TAA Compliance