Options to optimize the performance or functionality of room cooling products
Options to optimize the performance or functionality of room cooling products
Options to optimize the performance or functionality of room cooling products
Options to optimize the performance or functionality of room cooling products
Options to optimize the performance or functionality of room cooling products
Options to optimize the performance or functionality of room cooling products
Options to optimize the performance or functionality of room cooling products
Feature-rich rack enclosure optimized for easy installation, managing cables, integrating power distribution, and maximizing airflow.
Options to optimize the performance or functionality of room cooling products
Active Airflow ControlMonitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.Dew point monitoringPrevents condensation from forming inside the enclosure by dissuading access when the external dew point is above supply air temperature.Hot swappable fansAllows system to remain operational if a fan replacement is required.Leak detectionNotifies user in the event of a water leak within the coiling unit.Top and bottom chilled water connectionsAllows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.Washable filtersEasy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.InRow Chilled Water CoolingFeatures & BenefitsAvailabilityDual A-B power inputsDraws power from the UPS for power protection with dual feeds for redundancy.Rack inlet controlRack inlet control guarantees inlet temperature to IT equipment.Top and bottom chilled water connectionsAllows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.Active response controlsMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.Predictable coolingPlacing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.ServiceabilityEasy service accessAllows for all serviceable components to be replaced/maintained by easily accessible panels/doors.AgilityModular designModular design provides scalable solutions to add cooling as demand increases.Scaleable densitiesAllows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.CastersProvides flexibility to move the unit to wherever cooling is required.ManageabilityReal-Time Capacity MonitoringReal-time display of current and available cooling.Microprocessor controllerProvides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.Building management system integrationSend alarms and data points allowing you to manage critical building infrastructure from a single system.Total Cost of OwnershipRow-based architectureCaptures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.Variable speed fansVariable speed fans reduce energy consumption during off-peak cooling periods.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA