Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault. Scalable runtime Allows additional run time to be quickly added as needed. Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature.
Resettable circuit breakersEnables a quick recovery from overload events.Field-replaceable power distribution panelEnsures compatibility with equipment that has different plug types.Multiple cable-entry pointsProvides flexibility of UPS placement in the room and easy access to install cabling to the terminal blocks.Locking cabinetPrevents unauthorized access to the UPS.AvailabilityDual mains inputIncreases availability by allowing the UPS to be connected to two separate power sources.Scalable runtimeAllows additional run time to be quickly added as needed.Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedGenerator compatibleEnsures clean, uninterrupted power to protected equipment when generator power is used.Automatic internal bypassSupplies utility power to the connected loads in the event of a UPS overload condition or fault.Battery modules connected in parallelDelivers higher availability through redundant batteries.
Hot-scalable power, runtime & distribution in a high-density single frame design. This high-efficiency 3-phase UPS scales as your data center grows up to 48kW/48kVA. Suitable for small & medium data center applications.Includes: Network Management Card, Start-Up Service.
Battery Module Frame Sycf40kf Schneider Electric Sa Sycf40kf Schneider Electric
Toolless Mounting Capabilities Units do not require additional tools to mount into APC NetShelter VX, which allows the users to quickly and easily mount units in the rear of the enclosure. Vertical Mounting Capabilities Easily mounts vertically in racks or enclosures and occupies zero U of valuable rack space, which allows more equipment in the rack. Units that mount vertically are optimized to fit in a NetShelter VX enclosures. - Remote Current Monitoring. - Single-branch power input. - Cord Retention Bracket Compatible.
APC Maintenance Bypass Panels , Input: 200V, 208V, 230V , Input Connections: Hard Wire 3-wire (2PH + G), Hard Wire 4-wire (2PH+N+G) , Output: 120V, 200V, 208V, 230V, Output Connections: Hard Wire 3-wire (2PH + G),Hard Wire 4-wire (2PH + N +G)
DCPM28HN54SH0 Features- Rack Mount1U rackmountable. Hardware included.- Paralleling CapabilityIncrease capacity, run time or redundancy by adding further units in parallel- Hot-swap rectifiersCost of ownership is reduced by the use of light weight, modular, true hot-swappable rectifiers which facilitate easy maintenance- Wide temperature rangeEquipment capable of operating in an extended temperature environment suits a wider range of applications and can reduce or remove the need for HVAC.- Serial ConnectivityUse any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.- Serial ConnectivityProvides management of the UPS via a serial port.- Input power factor correctionMinimizes installation costs by enabling the use of smaller generators and cabling.- Hot Expansion Capability- Modular Rectifiers- N+1 RedundancyMagnum XS Rectifier Features & BenefitsAvailability- N+1 RedundancySystem integrity is maintained even in the event of a rectifier failure ensuring maximum uptime and system availability- Paralleling CapabilityIncrease capacity, run time or redundancy by adding further units in parallel- Wide temperature rangeEquipment capable of operating in an extended temperature environment suits a wider range of applications and can reduce or remove the need for HVAC.Adaptability- Hot Expansion CapabilityProtects your investment in DC power by enabling expansion or configuration simply by adding additional rectifiers- Paralleling CapabilityIncrease capacity, run time or redundancy by adding further units in parallel- Input power factor correctionReduced utility and wiring costs. Increasingly a legislative or specification requirement.Manageability- Integrated Control CircuitryMonitoring and reporting of vital rectifier functions, control of output current and voltage.Serviceability- Hot-swap rectifiersCost of ownership is reduced by the use of light weight, modular, true hot-swappable rectifiers which facilitate easy maintenanceConvenience- Input power factor correctionReduced utility and wiring costs. Increasingly a legislative or specification requirement.