Marketing FeaturesLocal Current Monitoring DisplayThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.Local and web-based monitoringStatus available to customers both in the data center and remotelyAlarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.Wide range of input and output connectionsProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.AgilityWide range of input and output connectionsProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.Single input power sourceSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.Rack-MountableIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
UL 9540A tested Li-Ion Battery Cabinet, 10 battery modules (Type O) for Symmetra PX 250/500 UPS (UL standard).
Card chassis provides additional SmartSlots for APC UPSs. Features: Computer Interface Cable, Multiple Application Configuration, Optional Power Supply, Rack Mount, UPS Accessory Expansion, UPS Management Peripheral Chassis Includes - Mounting pads, User Manual
APC IT Power Distribution Module 3 Pole 4 Wire 60A IEC309 200cmA touch-safe Power Distribution Module (including circuit breaker, power cord, power connection, and circuit monitoring) that eliminates the need for hot work or shutdowns during expansion of the power distribution system.Network ManagementProvides proactive power and environmental management via web and/or SNMPInformation DisplaysIndicates the status of the AC sources powering the units, as well as indicates which source is set as the primary source and which source is currently supplying power to the load. This provides a visual depiction of the power flow from the input to the load. This allows the user to quickly glance at the power flow and status of the input sources without connecting to the unit.Smallest footprintMinimizes your real estate expensesSystem mobilityPDU equipment can easily be relocated to accommodate a changing data center environment.LCD displayAlpha-Numeric Display which displays system parameters and alarms.Multiple distribution optionsSuperior design flexibility enables a wide range of customer requirements to be addressed.InfraStruXure Manager CompatibleEnables centralized management via the APC InfraStruXure Manager.LED status indicatorsQuickly understand unit and power status with visual indicators.Modular Power Accessories Features & BenefitsSafetyEnhance user safety with isolation at all touch points and with positive locking mechanisms that reduce the risk of accidental disconnectionManageabilityPower monitoringMeasure and monitor power consumption and usage with branch circuit monitoring and output metering, which are included at no extra costQuick status information LEDsAccess status information about the performance of the Power Distribution ModuleConvenienceToolless installation of breakersInstall factory-assembled Power Distribution Modules in under ten minutes - no tools are requiredGlobal product offeringStandardization of the power distribution system across all corporate locations is easy - a variety of 1-phase and 3-phase Power Distribution Modules address the unique power requirements of data centers around the world
Network ManagementFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.Remote Individual Outlet ControlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)Local Current Monitoring DisplayThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)Power DelaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.Flash UpgradeableQuickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)Integrates with InfraStruXure CentralAn IT-ready, scalable monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
Intuitive LCD interfaceProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.Predictive replace battery dateDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.Energy meterProvides actual kilowatt hours of usage for energy conscious users.Sequenced shutdown and restartConfigure select outlet groups to shut down and turn on in a pre-determined order (for UPSs with switched outlet groups).InfraStruXure Central compatibleEnables centralized management via APC InfraStruXure® Central.Pure sine wave output on batterySimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.Single switched outlet groupSingle outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.High online efficiencyReduces utlility costs, generates less heat.SmartSlotCustomize UPS capabilities with management cards.Cold-start capableProvides temporary battery power when the utility power is out.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.
Battery-protected and surge-only outlets Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipmentSafety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.Battery and surge protected outletsBack up and protect your hardware and data during power outages, surges and spikes.Surge only outletsProtect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.Audible alarmsProvides notification of changing utility power and UPS power conditionsLED status displayQuickly understand unit and power status with visual indicators.
APC by Schneider Electric Smart-UPS 3000VA Rack-moutable UPS - 2U Rack-mountable - 3 Hour Recharge - 230 V AC Output - Sine Wave - 12 x Battery/Surge Outlet - TAA Compliance
UL 9540A tested Li-Ion Battery Cabinet with 10 battery modules (Type O) and 1ph SMPS for Symmetra PX 250/500 UPS (UL).
NetShelter SX 18U 1070mm Deep Side Panel (Qty 1)
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA