APC 19" Rack Mountable 24A Maintenance Service Bypass Panel- 100-240V; 30A; BBM; Hardwire Input/Output.
APC Power Module - 1400W - ENERGY STAR, TAA Compliance
APC UPS Replacement Battery RBC 55 18000 mAh 12 V DC Lead Acid Hot Swappable 3 Year Minimum Battery Life.
by Schneider Electric NetShelter 42-Outlets PDU - Metered - IEC 60309 60A (3P+PE) - 21 x IEC 60320 C13/C15/C19/C21, 21 x IEC 60320 C13/C15 - 230 V AC - Network (RJ-45) - 0U - Rack
APC by Schneider Electric Smart-UPS X SMX2200RMLV2U 2200 VA Rack-mountable UPS - 2U Rack-mountable - 3 Hour Recharge - 10 Minute Stand-by - 120 V Input - 120 V AC Output - Sine Wave - Serial Port - USB - 6 x NEMA 5-15R, 2 x NEMA 5-20R - 8 x Battery/Surge Outlet - TAA Compliance
APC AP7530 Basic Rack 1.92kVA PDU - 24 x NEMA 5-20R - 1.92kVA - Zero U Rack-mountable - TAA Compliance
APC by Schneider Electric Smart-UPS, Lithium-Ion, 2200VA, 120V with SmartConnect Port and Network Card - 2U - 2 Hour Recharge - 120 V Input - 120 V AC Output - Sine Wave - 2 x NEMA 5-20R, 6 x NEMA 5-15R - 8 x Battery/Surge Outlet - TAA Compliance
APC AP7811B by Schneider Electric Rack PDU, Metered, 2U, 30A, 208V, (12) C13s & (4) C19
AP7998BFeaturesRACK PDU,SWITCHED,ZEROU,12.5KW,208V,(21)C13&(3)C19;10 CORDSwitched Rack Power Distribution Units (PDUs) provide advanced load monitoring combined with remote on/off switching control of individual outlets for power cycling, delayed power sequencing, and outlet use management.Includes : Cord Retention Bracket(s) , Documentation CD , Installation Guide , Rack Mounting Brackets , RS-232 configuration cable , Toolless Mounting KitLocal and web-based monitoringStatus available to customers both in the data center and remotelyResettable circuit breakersEnables a quick recovery from overload events.Toolless Rack Mounting CapabilitiesServer cases do not require additional tools to mount into NetShelter Enclosures, which allows the users to quickly and easily mount units in the rear of the enclosure.Vertical Mounting CapabilitiesEasily mounts vertically in racks or enclosures and occupies zero U of valuable rack space, which allows more equipment in the rack. Units that mount vertically are optimized to fit in a NetShelter enclosures.AgilitySingle input power sourceSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.Wide range of input and output connectionsProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.Rack-MountableIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.Marketing FeaturesLocal Current Monitoring DisplayThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.Remote Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.Power DelaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.Remote Individual Outlet ControlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).AvailabilityAlarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)Flash UpgradeableQuickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.Power DelaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.Local Current Monitoring DisplayThe aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)Integrates with StruxureWare Data Center ExpertAn IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the networkNetwork Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.Remote Individual Outlet ControlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
APC Rack PDU 9000 Switched, ZeroU, 30A, 120/208V, (16) 5-20R (7) C13 (1) C19