APC UPS Network Management Card 2. Product type: Network management card, Certification: AS/NZS 3548 (C-Tick) A, EN 55022 A, FCC 15 A, GOST, ICES-003, VCCI A. Host interface: SmartSlot, USB connector type: USB Type-A. Security algorithms: 802.1x RADIUS, HTTPS, SNMP, SSH, SSH-2. Width: 4.76"" (121 mm), Depth: 4.25"" (108 mm), Height: 1.5"" (38 mm)
PresentationMaintenance bypass cabinet with transformer. The maintenance bypass isolates the UPS completely during service operations. The input transformer can be configured onsite for either 480V or 600V input and delivers 208V output. Compatible with 208V UPS.
ATEN's SP100 (SNMP card) is an UPS monitoring equipment. Allows connection of the UPS directly to the ethernet network through a RJ-45 connector without using RS-232 ports on the computer and without loading any individual UPS management software on the network server. User can remotely control the UPS and monitor UPS current status from any off site location. SP100 can communicate the status of a UPS and issue commands to it.1x SP1001x Installation CD1x User Instructions
Kirk key kit (SKRU) for the maintenance bypass cabinet. It locks the internal breakers to ensure the correct sequence during maintenance. It is installed by the Schneider Electric Field Service Representative during start-up.
Cable kit that includes power cables and signal cables for installation of 1 or several modular battery cabinets adjacent to the Galaxy UPS for external batteries. This cable kit is for use with the Galaxy VS Modular Battery Cabinet for 6 smart modular battery strings. One kit required for the full system.
UPS Maintenance Bypass Panel Keeps Equipment Powered During UPS MaintenanceThis wall-mount three-breaker maintenance bypass panel is compatible with Tripp Lite’s SUTX40K 3-phase UPS system. It allows you to reroute power around the UPS, providing an alternate path for electricity that keeps the connected load operational while the UPS is offline for maintenance or repairs.Features 3 Built-In Circuit Breakers to Isolate LoadsThree 4-pole circuit breakers – an AC input breaker, a maintenance bypass breaker and a maintenance isolation breaker – are connected to heavy-duty buswork and isolate the UPS system from its connected load with no loss of network availability. This allows the load to remain continuously powered without costly downtime. A Kirk-key interlock system enhances safety and security. Removable handles allow the panel’s trim cover to be removed for internal access. The 125A unit has a kAIC rating of 10K.Switching Between Normal and Bypass Modes Is EasyWhen a UPS needs maintenance, this UPS bypass panel keeps power supplied to components via its mechanical interlock system by switching power to the external bypass breaker. Simply unscrew the interlock switch, rotate the switch from the UPS AC input breaker (SW1) to the bypass breaker (SW2), then turn on the bypass breaker and turn off the UPS and isolation breaker (SW3) to perform UPS maintenance without service interruption.Convenient Wall-Mount InstallationMade of galvanized steel, the service bypass panel has rear mounting holes for installation on a smooth, solid wall (mounting hardware not included).
GUPXCK100SOSHPD Seismic Kit for GUTOR PXC UL 75/100 kVA UPS
PresentationMaintenance bypass cabinet with transformer. The maintenance bypass isolates the UPS completely during service operations. The input transformer can be configured onsite for either 480V or 600V input and delivers 208V output. Compatible with 208V UPS.
Seismic kit that includes anchoring brackets and anchors.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA