Tripp Lite SU16KRT-1TF 16,000VA / 16kVA / 14,400 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 14U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 8kVA, and non-redundant operation at loads between 8 and 16kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.- Tripp Lite SU16KRT 16kVA, 16,000VA / 14,400 watt on-line, double-conversion UPS system in 14U total rack/tower configuration- Unique configuration offers 16kVA non-redundant operation and automatic N+1 redundancy at load levels of 8kVA and under- Included Parallel PDU with manual bypass switch enables hot-swap replacement of power modules at any supported load level- Hardwire input; 2 L6-30R (208/240v), 8 C19 (208/240v), 8 5-15/20R (120v) and 4 5-15R (120v) outlets- Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V & 120V nominal- Expandable runtime with optional external battery packs- Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)- Battery independent restart- Highly efficient economy mode option- Optional SNMPWEBCARD, RELAYIOCARD and RELAYIOMINI interface modules available (RELAYIOMINI requires removal of USB interface module)- Applications utilizing the optional network communications card require two SNMPWEBCARD accessories (install one per included power module)- HID-compliant USB interface- Includes Free PowerAlert monitoring software; PowerAlert LOCAL, PowerAlert NSA and PowerAlert NMS for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices- Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (6 required)- Optional 2-9USTAND supports upright tower placement (2 required)- Supports Emergency Power Off (EPO) via built-in interface- Front panel LEDs and LCD readout with scroll controls- LED / LCD display panel rotates for viewing in rackmount or tower configurations- External battery packs are field replaceable and hot swappable
Tripp Lite SU20KRT-1TF 20,000VA / 20kVA / 18,000 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 14U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 10kVA, and non-redundant operation at loads between 10 and 20kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.- Tripp Lite SU20KRT-1TF 20kVA, 20,000VA / 18,000 watt on-line, double-conversion UPS system in 14U total rack/tower configuration- Offers enhanced fault-tolerance and reliability with N+1 configuration support and hot-swappable whole UPS replacement options- Unique configuration ties input, output and data connections of two standard 10kVA UPS systems via detachable parallel PDU to offer 20kVA non-redundant operation and automatic N+1 redundancy at load levels of 10kVA and lower- Included Parallel PDU with manual bypass switching enables hot-swappable replacement of either 10kVA power module at any supported load level, with no interruption to connected equipment- Hardwire input; 2 L6-30R (208/240v), 8 C19 (208/240v), 8 5-15/20R (120v) and 4 5-15R (120v) outlets- Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions- Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise- Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types- Maintains full-time sine wave output within 2% of selectable 208/240 and 120V nominal at 60Hz during brownouts as low 100V and overvoltages as high as 300V- Expandable runtime is supported with optional BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH; BP240V1037C-1PH; BP240V1407C-1PH external battery packs- Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs- Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement- Rack / tower configuration installs in 14 total rack spaces (14U) with a maximum installed depth of only 32.5 in. / 82.6 cm- PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted- Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA (Network Shutdown Agent) for larger networks and PowerAlert NMS (Network Management System) for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices- Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232 and USB interfaces- HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X- Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces- Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification- Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module)- Supports Emergency Power Off (EPO) via built-in interface- Included rail kit supports 14U 19 inch rackmount installation in 4 post racks- Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (5 required for SU20KRT-1TF)- Optional 2-9USTAND supports upright tower placement (2 required for SU20KRT-1TF)- Front panel LEDs and LCD readout with scroll controls and password option supports visual monitoring of all major UPS functions and advanced UPS settings for charge level, nominal voltage selection, frequency conversion and other operational parameters- LED / LCD display panel rotates for viewing in rackmount or tower configurations- Network-grade AC surge and noise suppression- Industrial mode option (factory preset) enables supports high current startup loads by momentarily switching to bypass mode in response to short duration overload conditions- Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (output de-rates by 25%)- External battery packs are field replaceable and hot swappable
Tripp Lite SU20KRTG 20,000VA / 20kVA / 18,000 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 12U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 10kVA, and non-redundant operation at loads between 10 and 20kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.Tripp Lite SU20KRTG 20kVA, 20,000VA / 18,000 watt on-line, double-conversion UPS system in 12U total rack/tower configurationUnique configuration offers 20kVA non-redundant operation and automatic N+1 redundancy at load levels of 10kVA and underIncluded Parallel PDU with manual bypass switch enables hot-swap replacement power modules at any supported load levelHardwire input; 8 C19 outletsMaintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominalSupports 50/60Hz operation for worldwide frequency compatibilityCompatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD and RELAYIOCARD (NOTE: Applications utilizing any supported network management card option, require the installation of two of the same model network card – install one card per included UPS power module)Optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilitiesPADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurationsExpandable runtime with optional external battery packsSome external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)Battery independent restart ensures automatic UPS power-up after lengthy power outages, even with expired batteriesIntelligent battery management system with temperature-compensated charging extends battery lifeHID-compliant USB interfaceUSB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralertOptional 2POSTRMKITHD supports installation in 2 post 19 inch racks (4 required)Optional 2-9USTAND supports upright tower placement (2 required)Supports Emergency Power Off (EPO) via built-in interfaceFront panel LEDs and LCD readout with scroll controlsLED / LCD display panel rotates for viewing in rackmount or tower configurationsExternal battery packs are field replaceable and hot swappableFrequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
The OMNIX350HG offers medical-grade UPS protection with built-in line-interactive voltage regulation. IEC320 plug and outlets, plus built-in isolation transformer with Faraday shield offer full isolation and remove common mode noise. Tested to CE/IEC 60601-1 as medical electrical equipment. 350VA power handling capacity supports computers, inter-networking equipment and other critical loads during commercial power failures. Line-interactive voltage regulation corrects brownouts as low as 159V back to normal 230V levels, saving battery reserves for use only during complete power failures. Includes two-line phone surge suppression and built-in USB communications port.This UPS contains a lead acid battery designed to be connected continuously to an AC power source, except during brief power outages. It is not intended for frequent charge/discharge cycles, such as mobile cart applications where the UPS is often disconnected from the power source. Using the OMNIX350HG in this type of application will void the battery warranty.
The SMX700HG medical-grade UPS system provides dependable battery backup and is fully compliant with UL 60601-1 regulations when plugged into a hospital-grade outlet, making it ideal for use in patient care vicinities. The 700VA/450W capacity provides up to 36 minutes of runtime for a half load or 14.5 minutes for a full load, so you can work through short power failures and perform an orderly system shutdown in a prolonged blackout.Built-in line-interactive voltage regulation corrects brownouts as low as 155V and overvoltages as high as 274V to normal 230V nominal output, without drawing battery power. The SMX700HG’s built-in isolation transformer with Faraday shield offers full isolation and removes common mode noise while maintaining full AC surge suppression in all modes. Cumulative leakage current of all connected equipment is less than 100 microamps.This UPS system features six IEC320 C13 hospital-grade outlets and has a hospital-grade IEC320 C14 plug on a 15-centimeter (six-inch) dongle. All six outlets provide both backup protection and surge protection, rated to 340 joules.The SMX700HG also features diagnostic LEDs, as well as a USB port and a DB9 serial port that work with free downloadable PowerAlert® software for safe, unattended system shutdown in the event of a prolonged power failure.This UPS contains a lead acid battery designed to be connected continuously to an AC power source, except during brief power outages. It is not intended for frequent charge/discharge cycles, such as mobile cart applications where the UPS is often disconnected from the power source. Using the SMX700HG in this type of application will void the battery warranty.
The APSX4048SW 4000W APS X Series 48V DC 220/230/240V AC Inverter/Charger is a reliable power source for a wide variety of tools and sensitive electronics at mobile, emergency and remote sites. With no fumes, fuel or excess noise, it's an excellent alternative to generator power. It's operable in single-phase mode or three-phase mode for high-capacity industrial and commercial installations.The DC-to-AC pure sine-wave inverter delivers network-grade power. Its automatic line-to-battery transfer switch and integrated charging system allow the unit to work as an extended-run UPS, standalone AC power source or vehicle inverter. It delivers 4000W of continuous power, 6000W up to one minute or 8000W of peak power up to 10 seconds during equipment startup or cycling. An automatic overload detector, cooling fan and resettable AC circuit breakers protect the unit from damage.Designed for easy installation in RVs, commercial and fleet vehicles and emergency vehicles, the APSX4048SW converts stored power from any 48V battery or automotive DC source to safe, stable, computer-grade AC power for unlimited runtime. When hardwired to an external AC source, the unit keeps the user-supplied batteries charged via a three-stage 1-70A selectable charging system while simultaneously delivering AC power to connected equipment. When used as a UPS, the APSX4048SW responds to blackouts and brownouts with an automatic, instantaneous transfer to battery-derived AC output.
APC Smart-UPS XL, 3000VA/2700W, Input 230V/Output 230V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model, Rack Height 3 U Includes: CD with software, Rack Mounting Brackets, Smart UPS signalling RS-232 cable, USB cable, User Manual Standard Lead Time: Usually in Stock
APC Smart-UPS RT 10kVA, 208V, rackmount w/kit, 12U, 16x 5-20R & 6x L6-20R & 3x L6-30R & 2x L14-30R NEMA outlets, w/2 transfo 208V to 120V
Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault. Scalable runtime Allows additional run time to be quickly added as needed. Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature.
Resettable circuit breakersEnables a quick recovery from overload events.Field-replaceable power distribution panelEnsures compatibility with equipment that has different plug types.Multiple cable-entry pointsProvides flexibility of UPS placement in the room and easy access to install cabling to the terminal blocks.Locking cabinetPrevents unauthorized access to the UPS.AvailabilityDual mains inputIncreases availability by allowing the UPS to be connected to two separate power sources.Scalable runtimeAllows additional run time to be quickly added as needed.Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedGenerator compatibleEnsures clean, uninterrupted power to protected equipment when generator power is used.Automatic internal bypassSupplies utility power to the connected loads in the event of a UPS overload condition or fault.Battery modules connected in parallelDelivers higher availability through redundant batteries.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA