Stay informed about your power with the CyberPower PDU33103 monitored 3-Phase PDU. Ideal for data centers and network closets, this unit provides power monitoring in real time over the network by using the CyberPower management console and the RJ45 Ethernet port for network connection or locally by using the LCD.The PDU33103 supports a 208V 20A input and includes 44 outlets. Other features include an interactive digital display with selectable background color, high operating temperature range, built-in web interface, and power event notifications. The CyberPower PDU33103 is protected by a three-year limited warranty.Power DistributionDelivers AC power to servers, equipment, and connected devices via a power distribution unit.Remote and Local MonitoringEnables offsite and onsite tracking of PDU vitals; provides outlet control for individual and networked clients.Automatic Event NotificationsProvide immediate updates about power events via email, SMS text, or SNMP traps.Digital DisplayProvides easy-to-read information about amperage, voltage, KW, IP address, and other PDU information.Multi-color LCD BackgroundUser selectable background color on digital display allows for easy classification of PDU based on application. The LCD turns red when there is an alert.High Operating Temperature RangeOperates in data center hot aisle up to 140˚F (60˚C).CyberPower Management ConsoleA hardware interface built into Monitored and Switched PDUs. Its functionality includes the ability to switch PDU outlets on and off, reboot connected equipment locally or remotely, schedule power cycling of attached equipment, and perform other tasks, such as load monitoring and event logging.Switch-Free DesignSafeguards against accidental power shut down.Upgradeable FirmwareDownloadable improvements (firmware updates) to programs that run the PDU.Long Input Power CordReaches distant power sources, allowing the PDU to be placed where it’s needed.Cord Retention TraySecures power cords, keeping them organized and accessible. Helps cords stay plugged in.Durable Metal HousingProtects internal components and resists damage from impact or abrasions within challenging industrial environments. Also extends the life of the product.Network-Grade Plugs and OutletsHighly-durable construction ensures the efficient distribution of power in demanding IT or industrial environments to servers, equipment, and connected devices.Three-Year Limited WarrantyCovers defects in materials and workmanship in the product under normal use and conditions within three years of the purchase date. See warranty for details.
Stay informed about your power with the CyberPower PDU33108 monitored 3-Phase PDU. Ideal for data centers and network closets, this unit provides power monitoring in real time over the network by using the CyberPower management console and the RJ45 Ethernet port for network connection or locally by using the LCD.The PDU33108 supports inputs between 200-240V and includes 42 IEC-320 outlets. Other features include an interactive digital display with selectable background color, high operating temperature range, built-in web interface, and power event notifications. The CyberPower PDU33108 is protected by a three-year limited warranty.Power DistributionDelivers AC power to servers, equipment, and connected devices via a power distribution unit.Remote and Local MonitoringEnables offsite and onsite tracking of PDU vitals; provides outlet control for individual and networked clients.Automatic Event NotificationsProvide immediate updates about power events via email, SMS text, or SNMP traps.Digital DisplayProvides easy-to-read information about amperage, voltage, KW, IP address, and other PDU information.Multi-color LCD BackgroundUser selectable background color on digital display allows for easy classification of PDU based on application. The LCD turns red when there is an alert.High Operating Temperature RangeOperates in data center hot aisle up to 140˚F (60˚C).CyberPower Management ConsoleA hardware interface built into Monitored and Switched PDUs. Its functionality includes the ability to switch PDU outlets on and off, reboot connected equipment locally or remotely, schedule power cycling of attached equipment, and perform other tasks, such as load monitoring and event logging.Switch-Free DesignSafeguards against accidental power shut down.Upgradeable FirmwareDownloadable improvements (firmware updates) to programs that run the PDU.Long Input Power CordReaches distant power sources, allowing the PDU to be placed where it’s needed.Cord Retention TraySecures power cords, keeping them organized and accessible. Helps cords stay plugged in.Durable Metal HousingProtects internal components and resists damage from impact or abrasions within challenging industrial environments. Also extends the life of the product.Network-Grade Plugs and OutletsHighly-durable construction ensures the efficient distribution of power in demanding IT or industrial environments to servers, equipment, and connected devices.Three-Year Limited WarrantyCovers defects in materials and workmanship in the product under normal use and conditions within three years of the purchase date. See warranty for details.
CyberPower PDU24004 provides output from a UPS unit, generator, or utility power to multiple connected devices in IT environments. Dual power cords can be plugged into separate power sources to provide redundancy to single-corded connected equipment. If the selected power source exceeds the desired thresholds or fails, the ATS PDU will automatically switch to the other power source to ensure continuous operation.The unit comes with a hot-swappable multifunction readout that displays real-time vitals including current, input voltage, power consumption levels in amps and watts. The digital LCD display is also color configurable, allowing easy maintenance and monitoring of the ATS PDU. Users can change LCD’s colors to easily categorize devices between multiple machines in server room and IT environments. The firmware can also be conveniently upgraded via the USB port, ensuring the latest features and updates are available for users.
CyberPower PDU24005 provides output from a UPS unit, generator, or utility power to multiple connected devices in IT environments. Dual power cords can be plugged into separate power sources to provide redundancy to single-corded connected equipment. If the selected power source exceeds the desired thresholds or fails, the ATS PDU will automatically switch to the other power source to ensure continuous operation.The unit comes with a hot-swappable multifunction readout that displays real-time vitals including current, input voltage, power consumption levels in amps and watts. The digital LCD display is also color configurable, allowing easy maintenance and monitoring of the ATS PDU. Users can change LCD’s colors to easily categorize devices between multiple machines in server room and IT environments. The firmware can also be conveniently upgraded via the USB port, ensuring the latest features and updates are available for users.The product can be connected to a PC through the serial port to perform local control of the ATS PDU.
CyberPower Switched ATS PDU PDU24005 10-Outlets PDU - Metered - NEMA L5-20P - 10 x NEMA 5-20R - 120 V AC - 1U - Horizontal - Rack-mountable
CyberPower PDU13102 27-Outlets PDU - NEMA L21-20P - 21 x NEMA 5-20R, 6 x NEMA L6-20R - 230 V AC - 0U - Vertical - Rack-mountable
CyberPower PDU13103 42-Outlets PDU - Basic - NEMA L21-20P - 36 x IEC 60320 C13, 6 x IEC 60320 C19 - 230 V AC - 0U - Vertical - Rack-mountable
CyberPower PDU13104 36-Outlets PDU - Basic - Hubbell CS8365C - 30 x IEC 60320 C13, 6 x NEMA L6-20R - 230 V AC - 0U - Vertical - Rack-mountable
CyberPower PDU13101 42-Outlets PDU - NEMA L21-20P - 42 x NEMA 5-20R - 230 V AC - 0U - Vertical - Rack-mountable
The CyberPower PDU20SWHVT10ATNET, 10-outlet 1U rack mount switched auto transfer switch (ATS) power distribution unit (PDU), provides 200-240V / 20A output. The PDU distributes unfiltered electrical pass-through to 10 IEC-320 (8) C13 / (2) C19 receptacles from redundant NEMA L6-20P plugs. Dual power cords can be plugged into separate power sources to provide redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable.The PDU20SWHVT10ATNET includes a SNMP/HTTP card (RMCARD203). With the SNMP card and an IP address on the network interface, users have real-time monitoring and outlet control of the ATS PDU. The switched outlet receptacles can be managed individually or collectively over the network the CyberPower Management Console /web browser and the RJ45 Ethernet port for network connection or, locally, using the LCD controls. Using the CyberPower Management Console, outlets can be turned on, turned off, or recycled on demand or at programmed times, to address multiple needs, including remote rebooting of locked equipment, load shedding, power sequencing, and locking out unauthorized loads. Additionally, the CyberPower Management Console provides real-time remote monitoring of PDU vitals and event logging to review historical power conditions, such as input voltages, load levels, and outlet status. Automatic event notifications can be sent to designated users when power events occur, via Email, SMS Text, or SNMP Trap.The LCD provides local monitoring of the PDU and on/off control the outlets. Perform load management by using the display to measure the electrical current (displayed in amperes) used by connected equipment. The LCD can also display input and output voltages, to diagnose potential issues with input AC power. Active power consumption (displayed in kilowatts) and hardware and firmware versions are also viewable on the LCD screen.Designed for datacenters and other demanding electrical applications, the PDU20SWHVT10ATNET has a rugged, industrial-grade metal housing, a 10-foot AC power cord, and a cord retention tray. It can be mounted horizontally and is UL60950_1 and CSA C22.2 certified by ETL and FCC Class A certified. A three-year warranty ensures that this PDU is free of defects in design, assembly, material or workmanship.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA